Calibrating the HXMT collimators using diffuse illumination
Calibrating the HXMT collimators using diffuse illumination作者机构:Department of Engineering Physics & Center for Astrophysics Tsinghua University Beijing China Key Laboratory of Particle Astrophysics Institute of High Energy Physics Chinese Academy of Sciences Beijing China
出 版 物:《Science China(Physics,Mechanics & Astronomy)》 (中国科学:物理学、力学、天文学(英文版))
年 卷 期:2010年第53卷第S1期
页 面:36-39页
核心收录:
基 金:supported by the National Basic Research Program of China (Grant No. 2009CB824-800)
主 题:HXMT collimator point spread function Monte Carlo simulation diffuse illumination
摘 要:We propose a new method to calibrate the HXMT collimators by measuring the optical point spread function(PSF) of the hard X-ray modulation telescope(HXMT).The light transmission of the collimator at different viewing angles with a camera and a diffuse backlight placed behind the collimator is *** method is much easier to accomplish than measuring the PSF with a parallel optical *** experimental results are very consistent with the *** PSF of the collimator of the high energy X-ray telescope on HXMT is found to be in good agreement with the design,with accuracy better than 1 arcmin.