咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >The effects of ultrasonic irra... 收藏

The effects of ultrasonic irradiation in combination with ozone on the reduction of residual ethion of tangerine (<i>Citrus reticulata</i>Blanco cv. Sai Nam Pung) fruit after harvest

The effects of ultrasonic irradiation in combination with ozone on the reduction of residual ethion of tangerine (<i>Citrus reticulata</i>Blanco cv. Sai Nam Pung) fruit after harvest

作     者:Kanda Whangchai Satit Phiyanalinmat Jamnong Uthaibutra Sarunya Pengphol Nakao Nomura 

作者机构:1Postharvest Technology Innovation Center Commission on Higher Education Bangkok Thailand 2Postharvest Technology Research Institute Chiang Mai University Chiang Mai Thailand 3Postharvest Technology Research Institute Chiang Mai University Chiang MaiThailand Department of Industrial Chemistry Faculty of Science Chiang Mai University Chiang Mai Thailand Faculty of Agriculture and Industrial TechnologyNakonsawan Rajabhat University Nakonsawan Thailand Graduate School of Life and Environmental Science University of Tsukuba 1-1-1 Tennodai Tsukuba lbaraki Japan 

出 版 物:《Agricultural Sciences》 (农业科学(英文))

年 卷 期:2013年第4卷第5期

页      面:7-11页

学科分类:1002[医学-临床医学] 100214[医学-肿瘤学] 10[医学] 

主  题:Tangerine Ethion Pesticide Residue Ozone Ultrasonic Irradiation 

摘      要:Ethion residue removal efficiency using individual and combined effects of ultrasonication (US), ozonation (O3), ultrasonication and ozonation (US/O3) was investigated. A 1 mg·L-1 standard ethion was subjected to an ultrasonic irradiation (3W input power) device with different frequencies of 108, 400, 700, 1000 kHz, and to an ozone with a concentration of 200 mg· mL-1 with various exposure times (0, 15, 30, 45 and 60 minutes). Reduction of residual ethion was determined by gas chromatography with flame photometric detection (GC-FPD). It was found that 1000 kHz ultrasonic irradiation for 60 minutes was the most effective treatment for reducing ethion concentration. Additionally, ozone could reduce the concentration of standard ethion after 60 minutes of exposure. Ultrasonic irradiation in combination with ozone had a synergistic effect in reducing standard ethion concentration, with the highest rate occurring within the first 15 minutes. Ethion concentration was reduced to 75.43% after ultrasonic irradiation at 1000 kHz and ozone exposure for 60 minutes. The effectiveness of the combined scheme for reducing of ethion residues on tangerine was also determined by GC-FPD. The ethion residue on fresh tangerines after ultrasonic irradiation and ozone washing was reduced by 73.03% after 60 minutes. The present study demonstrates that ultrasonic irradiation and ozone exposure could be used to reduce ethion residues in treated tangerine in order to meet the Standards for Pesticide Residue Limits.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分