咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Estimation of Endotracheal Tub... 收藏

Estimation of Endotracheal Tube Cuff Pressure in a Large Teaching Hospital in Ghana

Estimation of Endotracheal Tube Cuff Pressure in a Large Teaching Hospital in Ghana

作     者:Ebenezer Owusu Darkwa Frank Boni Eugenia Lamptey Yaw Adu-Gyamfi Christian Owoo Robert Djagbletey Alfred Edwin Yawson Edmund Ayesu Daniel Akwanfo Yaw Sottie 

作者机构:Department of Anaesthesia School of Medicine and Dentistry College of Health Sciences University of Ghana Accra Ghana Department of Community Health School of Public Health College of Health Sciences University of Ghana Accra Ghana Department of Statistics Kumasi Polytechnic Kumasi Ghana Department of Anaesthesia Korle-Bu Teaching Hospital Accra Ghana 

出 版 物:《Open Journal of Anesthesiology》 (麻醉学期刊(英文))

年 卷 期:2015年第5卷第12期

页      面:233-241页

学科分类:1002[医学-临床医学] 100214[医学-肿瘤学] 10[医学] 

主  题:Endotracheal Tube Cuff Pressure Physician Anaesthetist Nurse Anaesthetist Korle-Bu Teaching Hospital 

摘      要:Background: Maintenance of optimal Endotracheal Tube cuff Pressure (ETTcP) in anaesthetic practice reduces cuff pressure complications. Aneroid manometers for measurement of ETTcP are not widely available in Ghana, hence anaesthesia providers estimate ETTcP according to their experience. The study assessed ETTcP obtained from estimation techniques between anaesthesia providers at Korle-Bu Teaching Hospital (KBTH). It also evaluated the Volume of Air Required (VAR) to obtain an acceptable cuff inflation pressure for sizes 7.0 and 8.0 mm adult endotracheal tubes used at the hospital, and the effect of patient’s age, weight and height on this volume. Methods: Eighty-one patients who underwent general anaesthesia were recruited. ETTcP was measured using an aneroid manometer via a three-way tap. After full cuff deflation, the cuff was refilled with air until an ETTcP of 20 cm H2O was obtained. Independent t-test was used to measure the statistical variations in the ETTcP using estimation techniques in relation to recommended levels as well as the significant difference of mean VAR to obtain a cuff pressure of 20 cm H2O. Grouped t-test was used to determine significant differences in ETTcP between anaesthesia providers using estimation techniques. Results: Mean ETTcP obtained from estimation techniques was (61.87, 73.79) cm H2O. The mean ETTcP measured for Physician and Nurse Anaesthetists were 65.36 cm H20 and 69.52 cm H2O respectively. The mean VAR to achieve an ETTcP of 20 cm H2O for endotracheal tube sizes 7.0 mm and 8.0 mm were 3.90 ± 1.13 mls and 4.55 ± 0.95 mls respectively. Age and weight significantly influenced the VAR to achieve a cuff pressure of 20 cm H2O, however, height did not. Conclusions: This study demonstrated that cuff pressures obtained by estimation techniques were generally higher than the recommended average with no significant difference between anaesthesia providers. However, in the absence of an aneroid manometer, ETTcP of tube sizes 7.0 mm and

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分