An Optical Sensor Based on Polyvinyl Benzyl Malonate Cross-Linked with Divinyl Benzene Dispersed in a Hydrogel Membrane for Detection of Some Heavy Metals

An Optical Sensor Based on Polyvinyl Benzyl Malonate Cross-Linked with Divinyl Benzene Dispersed in a Hydrogel Membrane for Detection of Some Heavy Metals

作     者:Imad Odeh Ziad Shakhsher Suha Jaber Mahmood Khateeb Fuad Al-Rimawi 

作者机构:Faculty of Science and Technology Al-Quds University East Jerusalem Palestine 

出 版 物:《American Journal of Analytical Chemistry》 (美国分析化学(英文))

年 卷 期:2012年第3卷第4期

页      面:283-287页

学科分类:07[理学] 0703[理学-化学] 

主  题:Shrinking Microsphere Polymer Polyvinylbenzylmalonate Optical Chemical Sensors Heavy Metal Sensing Equilibrium Formation Constant 

摘      要:In previous work we have developed a dicarboxylate functionalized polymer that demonstrated chemical sensing. It showed good response to pH changes as well as to varying concentrations of copper and calcium ions. Our recent in-vest- tigations showed interesting results upon testing the functionalized sensing polymer on heavy metals. This sensor is composed of microspheres of polyvinyl benzyl malonate lightly-cross-linked with divinyl benzene dispersed in a hydrogel membrane. The response of the optical sensor is based on the interaction between the metal cations with the deprotonated functional group. The polymer, thus, undergoes shrinking as a result of neutralization of adjacent negative charges on the back-bone of the polymer. This causes significant changes in the optical properties of the sensing element. The optical changes were measured as absorbance vs. wavelength as the sensing membrane is exposed to solutions of varying concentrations of heavy metal ions. The sensor showed significant increase in absorbance up to a concentration of 5 × 10-3 M to the following metal ions: Ni2+, Zn2+, and Cd2+. Furthermore, the studied capacity of the derivatized microspheres showed close values to Ni2+, Zn2+, Cd2+ (1.20, 1.09, 1.08 mmol/g respectively). These kinds of properly functionalized polymers appear to be suitable, versatile sensing elements for the detection of low concentrations of heavy metal ions. In addition, all of the tested heavy metals showed a similar value of the equilibrium formation constant, (log Kf1 is 2.63). In contrast, the sensor showed no significant response to varying concentrations of K+ and Mg2+ metal ions.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分