咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Safety and efficacy of amplatz... 收藏

Safety and efficacy of amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up

Safety and efficacy of amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up

作     者:Muhammad Dilawar Zaheer Ahmad 

作者机构:Hamad General Hospital Doha Qatar Southampton University Hospital Southampton UK 

出 版 物:《World Journal of Cardiovascular Diseases》 (心血管病(英文))

年 卷 期:2013年第3卷第2期

页      面:228-233页

学科分类:1002[医学-临床医学] 100201[医学-内科学(含:心血管病、血液病、呼吸系病、消化系病、内分泌与代谢病、肾病、风湿病、传染病)] 10[医学] 

主  题:Ventricular Septal Defect Amplatzer Duct Occluder Aneurysm 

摘      要:Objectives: Different devices including Amplatzer duct occluder has been used for percutaneous closure of ventricular septal defects. This study reports our medium term follow up of perimembranous and muscular ventricular septal defects with tunnel shape aneurysm closure using the Amplatzer duct occluder. Materials and Methods: From May 2006-December 2012, we used Amplatzer duct occluder in seven ventricular septal defect patients here atHamad General Hospital,Doha,Qatar. There were 4 male and 3 female patients with an age range of 4 - 32 years with a median of 8 years and weight range of 16 - 63 kgwith a median of33 kg. In this group, 6 were perimembranous and 1 muscular and all these ventricular septal defects had a tunnel shape aneurysm. Transesophageal echocardiographic diameter ranged from 4 - 8 mmand Qp/Qs was 1 - 1.6. Angiographically, the diameter on the left ventricular side measured 3.5 - 10 mmand on right ventricular side 2.4?- 5 mm. 8/6 mmAmplatzer duct occluder was used to close these ventricular septal defects. Results: There were no major complications and immediately after the procedure there was no residual shunt in any of these patients and all the patients remained in normal sinus rhythm. One patient was expatriate and no further follow up was available. The rest of the 6 patients had 1 - 80 months with a median of 54 months follow up and none of these patients had any residual shunt and all remained in normal sinus rhythm. Two patients developed trivial aortic valve regurgitation immediate post procedure, one remained unchanged and the 2nd has progressed to mild at this latest follow up. Conclusion: Amplatzer duct occluder is feasible and a safe device for percutaneous closure of selective tunnel shape aneurysmal perimembranous and muscular ventricular septal defects.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分