咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Experimental Studies on Therma... 收藏

Experimental Studies on Thermal Performance of a Pulsating Heat Pipe with Methanol/DI Water

Experimental Studies on Thermal Performance of a Pulsating Heat Pipe with Methanol/DI Water

作     者:Bhawna Verma Vijay Lakshmi Yadav Kaushal Kumar Srivastava 

作者机构:Department of Chemical Engineering Indian Institute of Technology Banaras Hindu University Varanasi India 

出 版 物:《Journal of Electronics Cooling and Thermal Control》 (电子器件冷却与温度控制期刊(英文))

年 卷 期:2013年第3卷第1期

页      面:27-34页

学科分类:080702[工学-热能工程] 08[工学] 0807[工学-动力工程及工程热物理] 

主  题:Pulsating Heat Pipe Start-Up Power Working Fluid Thermal Resistance Heat Transfer Coefficient 

摘      要:The effect of working fluid on the start-up and thermal performance in terms of thermal resistance and heat transfer coefficient of a pulsating heat pipe have been studied in the present paper. Methanol and de-ionized water has been selected as the working fluid. The minimum startup power for DI water was obtained at 50% filling ratio and for methanol at 40%. The optimum filling ratio in terms of minimum startup power and minimum thermal resistance was 50% for DI water and 40% for methanol. The minimum thermal resistances for DI water and methanol were observed at vertical orientation. The evaporator side heat transfer coefficient for water was slightly more, while the condenser side heat transfer coefficient was appreciably more than that of methanol. Studies were also conducted for start-up time and temperature at different orientations and it was found that the PHP charged with methanol worked efficiently at all orientations.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分