咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >High Contact Pressure Resultin... 收藏

High Contact Pressure Resulting from Bone Marrow Puncture

High Contact Pressure Resulting from Bone Marrow Puncture

作     者:Hiroshi Fujita Junji Tomiyama Shigeko Nishimura 

作者机构:Department of Internal Medicine Tokyo Metropolitan Bokutoh Hospital Tokyo Japan Department of Transfusion Medicine Tokyo Metropolitan Bokutoh Hospital Tokyo Japan 

出 版 物:《Open Journal of Blood Diseases》 (血液病期刊(英文))

年 卷 期:2012年第2卷第3期

页      面:56-58页

学科分类:1002[医学-临床医学] 100214[医学-肿瘤学] 10[医学] 

主  题:Bone Marrow Aspiration Cardiac Tamponade Contact Pressure Iatrogenic Accident 

摘      要:Cardiac tamponade following sternal puncture is fatal and is caused by an anomaly such as foramen sterni, fragility of the bone, or high pressure exerted by doctors on the bone. Contact pressure associated with bone marrow aspiration is unknown;therefore, we examined the contact pressure resulting from bone marrow puncture for aspiration. Prescale, a pressure-sensitive film, was used for measurements. Contact pressure on wood surface at 2 heights, the knee and hip positions of the hematologists, was examined and was approximately 15 - 21 megapascals. The magnitude of the con-tact pressure did not change with the type of puncture needle. However, the contact pressure in the needle area at the hip position was higher than that at the knee position height, when doctors aspirated the bone marrow. Contact pressure resulting from bone marrow puncture was found to be high;therefore, hematologists should be aware of this force when dealing with patients.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分