Review on Mould Contamination and Hygrothermal Effect in Indoor Environment
Review on Mould Contamination and Hygrothermal Effect in Indoor Environment作者机构:School of Civil Engineering University of South China Hengyang China Engineering Lab of Hunan for the Technologies of Building Environment Control University of South China Hengyang China Key Lab of Hunan for the Technologies of Energy Conservation in Prefabricated Buildings University of South China Hengyang China
出 版 物:《Journal of Environmental Protection》 (环境保护(英文))
年 卷 期:2018年第9卷第2期
页 面:100-110页
学科分类:1002[医学-临床医学] 100214[医学-肿瘤学] 10[医学]
主 题:Mould Contamination Building Environment Mould Growth Model Heat and Moisture Transfer
摘 要:Mould is an important factor which affects building environment and indoor air quality. Firstly, a variety of damages of mould contamination to human and building are reviewed. Then, the crucial factors of mould growth are analyzed;temperature and humidity are key factors. After that, the indoor mould growth models were analyzed. Heat and moisture transfer in building envelope is a key factor which affects mould growth environment;wall is sensitive to reach the critical condition which leads to mould growth and reproduction, results in contamination.