Self-Adjusting Characterization for Steady-State, Direct Current Cathode-Dominated Glow Discharge Plasmas at High Pressures
为在高压力的不变的、直接当前的阴极主导的发光分泌物血浆的自动调节的描述作者机构:CAS Key Laboratory of Basic Plasma PhysicsDepartment of Modern PhysicsUniversity of Science and Technology of ChinaHefei 230026 Institute of Plasma PhysicsChinese Academy of SciencesHefei 230031
出 版 物:《Chinese Physics Letters》 (中国物理快报(英文版))
年 卷 期:2013年第30卷第8期
页 面:107-109页
核心收录:
学科分类:07[理学] 070204[理学-等离子体物理] 0702[理学-物理学]
基 金:Supported by the National Natural Science Foundation of China under Grant No 11075158 the Fund for Fostering Talents in Basic Science of the National Natural Science Foundation of China(No J1103207)
摘 要:A steady-state,direct-current high-pressure CH_(4)-H_(2) glow discharge in a cup-shaped cathode parallel to anode configuration is investigated by using their V–I characteristics and CCD *** discharges display an abnormal glow feature,and an expansion of a negative glow is observed on the cathode sidewall with the increasing discharge *** exists a dependence of voltage on gas pressure for different fixed *** voltage decreases with gas pressure initially,and then increases conversely,which is correlated with the glow states of the cathode *** study exhibits a self-adjusting characterization for plasmas in cathode fall,which is important for maintaining steady-state,abnormal glow discharge in a relatively high pressure range.