咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Significantly enhanced flashov... 收藏

Significantly enhanced flashover voltage of epoxy in vacuum by graded surface roughness modification

作     者:Inzamam Ul Haq Feipeng Wang Shakeel Akram Muneeb Ahmed Muhammad Tariq Nazir Inzamam Ul Haq;Feipeng Wang;Shakeel Akram;Muneeb Ahmed;Muhammad Tariq Nazir

作者机构:State Key Laboratory of Power Transmission Equipment&System Security and New TechnologyChongqing UniversityChongqingChina College of Electrical Engineering and Control ScienceNanjing Tech UniversityNanjingChina State Key Laboratory of Electrical Insulation and Power EquipmentXi'an Jiaotong UniversityXi'anChina School of EngineeringRMIT UniversityMelbourneVictoriaAustralia 

出 版 物:《High Voltage》 (高电压(英文))

年 卷 期:2023年第8卷第5期

页      面:997-1010页

核心收录:

学科分类:080801[工学-电机与电器] 0808[工学-电气工程] 08[工学] 0805[工学-材料科学与工程(可授工学、理学学位)] 080502[工学-材料学] 

基  金:National Natural Science Foundation of China,Grant/Award Number:92166206 Fundamental Research Funds for the Central Universities,Grant/Award Number:2022CDJQY‐014 111 Project of the Ministry of Education of China,Grant/Award Number:BP0820005 

主  题:flash graded roughness 

摘      要:The flashover strength of epoxy(EP)insulations in the High voltage direct current applications of future energy grids can be improved by tailoring their surface *** work aims to improve the DC surface flashover characteristics of EP after being treated with sandpaper of different *** with virgin EP and homogenously modified EP considering varying surface roughness(R_(a)=0.54,3.16,5.24,and 8.35μm)are *** experimental characterisations,such as water contact angle,surface intrinsic conductivity,surface voltages,flashover strength,and trap distributions are conducted and evaluated to analyse the difference between virgin and treated ***,based on the obtained experimental results of homogenously treated EP and theoretical analysis,the concept of surface functionally graded materials(SFGMs)is put *** flashover voltages of homogenously treated EP are augmented significantly compared to virgin EP regardless of the voltage polarity and enhanced by enhancing the surface *** sample T_(Model‐C) with SFGM design shows a 45.02%and 43.75%improvement in the negative and positive flashover voltages than that of the virgin *** the end,COMSOL simulations are conducted to justify the experimental findings and to analyse the difference between virgin and modified samples in terms of electric field distribution.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分