Determination of Trace Rare Earth Elements in Biological Samples by ICP-AES with Tungsten-spiral Electrothermal Vaporization Sampling
Determination of Trace Rare Earth Elements in Biological Samples by ICP-AES with Tungsten-spiral Electrothermal Vaporization Sampling作者机构:Department of chemistrywuhan UniversityWuhan 430072China Author to whom correspondence should be sent
出 版 物:《Journal of Rare Earths》 (稀土学报(英文版))
年 卷 期:1993年第11卷第1期
页 面:52-57页
核心收录:
学科分类:080603[工学-有色金属冶金] 08[工学] 0806[工学-冶金工程]
主 题:Tungsten-spiral electrothermal vaporization sampling ICP-AES REE Biological sample
摘 要:A method for determination of trace rare earth elements in biological sample by ICP-AES with tungsten-spiral electrothermal vaporization(TETV-ICP-AES)sampling has been developed in this work. Several influencing factors including desolvation and vaporization parameters,carrier gas flow rate and ma- trix effect were investigated in *** optimal experimental conditions,the detection limits for La,Nd, Gd,Dy,Ho,Yb,Lu and Y were obtained in the range of 10^(-9)~10^(-11) g,and they are comparable to and,in most instances,better than those for the GFAAS and conventional pneumatic *** precision(RSD)obtained for this method is less than 6%.