Flexibility Improvement of CHP Unit for Wind Power Accommodation
Flexibility Improvement of CHP Unit for Wind Power Accommodation作者机构:School of Control and Computer EngineeringNorth China Electric Power UniversityBeijingChina
出 版 物:《Journal of Modern Power Systems and Clean Energy》 (现代电力系统与清洁能源学报(英文))
年 卷 期:2022年第10卷第3期
页 面:731-742页
核心收录:
学科分类:0808[工学-电气工程] 08[工学] 0807[工学-动力工程及工程热物理]
基 金:supported in part by the National Natural Science Foundation of China(No.51806063)
主 题:Combined heat and power(CHP) flexibility bypass low-pressure cylinder(LPC)removal heat storage tank electric boiler
摘 要:Improving the flexibility of combined heat and power(CHP)units is an important way to solve the problem of wind power accommodation in northern ***,this paper analyzes the principle of an extraction-type CHP unit,calculates its safe operation range,and analyzes its contradiction between heating and ***,the safe operation ranges of the CHP unit with several flexibility modifications are further calculated,which involve two-stage bypass,low-pressure cylinder(LPC)removal,heat storage tank,and electric ***,based on the safe operation ranges,their effects on improving the capabilities of deep peak shaving and wind power accommodation are compared,and their adaptabilities to different wind scenarios are *** results show that:①all flexibility modifications can improve the deep peak shaving capability of the CHP unit,especially for the two-stage bypass and the electric boiler;②LPC removal modification can accommodate wind power to some extent,but most of wind power is still abandoned;③heat storage tank modification is unstable in different wind scenarios,which is determined by the surplus heating capability during the daytime.