文献详情 >A Modulation Method with Unfix... 收藏
A Modulation Method with Unfixed Switching Frequency Based o...

A Modulation Method with Unfixed Switching Frequency Based on Output Power for Wind Power Converter

作     者:Jing-yang HUANG Gang ZHANG Wei-jun PAN 

作者单位:Air Traffic Management College Civil Aviation Flight University of China School of Automation Engineering the University of Electric and Science Technology of China 

会议日期:2020年

学科分类:080801[工学-电机与电器] 0808[工学-电气工程] 08[工学] 0807[工学-动力工程及工程热物理] 

基  金:financially supported by the National Key Research and Development Program: 2016YFB0502403 

关 键 词:Harmonic THD Wind power converter Switching frequency Power loss 

摘      要:The wind turbine power system is being widely used and heavily connected to the utility grid, and the total harmonic distortion(THD) is one of the major evaluation indicators of electric power quality. The characteristics of the grid-connected wind converter harmonic with variable power loading are analyzed in this paper, and a software method of the variable switching frequency based on the output power of wind power converter is investigated to improve the grid-connecting harmonic considering the widely power loading. The method is verified on a three-level Neutral-Point-Clamped converter with Sinusoidal Pulse Width Modulation through simulations at last. And the results show that the THD is improved clearly and meanwhile the power loss and junction temperature are improved.