咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Comparison of circumferential ... 收藏
Comparison of circumferential pulmonary vein anatomy mapping...

Comparison of circumferential pulmonary vein anatomy mapping in patients with atrial fibrillation guided by Carto mapping system and high-density mesh mapping catheter

作     者:Yiwen Yan,Gang Chen,Songwen Chen,Feng Zhang,Weidong Meng,Shaowen Liu Shanghai First People’s Hospital,Affliated to Jiaotong University 200000 

会议名称:《中华医学会心电生理和起搏分会第十次全国学术年会》

会议日期:2012年

学科分类:1002[医学-临床医学] 100201[医学-内科学(含:心血管病、血液病、呼吸系病、消化系病、内分泌与代谢病、肾病、风湿病、传染病)] 10[医学] 

摘      要:Objective Catheter-based pulmonary vein isolation(PVI) is an established therapy to treat patients with paroxysmal atrial *** high-density mesh mapper(HDMM),a novel multi-electrode circumferential mapping catheter,guides the circumferential atrium isolation without help of 3D electro-anatomic *** compared the difference of the circumferential pulmonary vein anatomy mapping guided between by Carto system(one 3D electro-anatomic mapping system) and by HDMM. Methods From August 2010 to February 2012,forty-four consecutive patients with paroxysmal atrial fibrillation were scheduled for a first procedure of PVI.A circumferential PV ostial anatomy map was set up in Carto system around the HDMM(HDMM,Bard Electrophysiology) firstly,while the operator was blinded to the Carto ***-guided PVI was performed in every patient by irrigated radiofrequency application,which established another circumferential PV(CPV) ostial anatomy *** study compared the difference between the two images,including the point-to-point straight distance,the area,the perimeter and so on. Results All 176 PVs in 44 patients could be mapped by the HDMM and *** 43.2%of the PV ostial anatomies were matched very well between the two different map *** point-to-point straight distance between the HDMM-guided map and Carto-guided map is(6.20±1.44)*** distance in some PV segments between the two images is *** area of circumferential right PV(CRPV) in the two views is 8.41±2.88mm in Carto map,9.37±1.84 mm in HDMM map respectively(P=0.013). The area of circumferential left PV(CLPV) is(8.12±2.48)mm in Carto,(8.98±2.33) mm in HDMM respectively(P=0.071).The CRPV perimeter in Carto and HDMM is(11.63±1.95)mm vs (11.87±1.72)mm(P=0.471),the CLPV(11.29±1.59)mm vs(11.12±1.71)mm(P=0.573). Conclusion Compared to the Carto-guided CPV anatomy image,the HDMM-guided one still has some discrepancies,which maybe explain a part of reasons why the high-density mesh ablator(

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分