文献详情 >Feasibility Analysis of the Op... 收藏

Feasibility Analysis of the Operation Strategies for Combined Cooling, Heating and Power Systems (CCHP) based on the Energy-Matching Regime

Feasibility Analysis of the Operation Strategies for Combined Cooling,Heating and Power Systems (CCHP) based on the Energy-Matching Regime

作     者:FENG Lejun DAI Xiaoye MO Junrong SHI Lin FENG Lejun;DAI Xiaoye;MO Junrong;SHI Lin

作者机构:Key Laboratory for Thermal Science and Power Engineering of Ministry of EducationDepartment of Energy and Power EngineeringTsinghua UniversityBeijing 100084China 

出 版 物:《Journal of Thermal Science》 (热科学学报(英文版))

年 卷 期:2020年第29卷第5期

页      面:1149-1164页

核心收录:

学科分类:080702[工学-热能工程] 08[工学] 0807[工学-动力工程及工程热物理] 0805[工学-材料科学与工程(可授工学、理学学位)] 0702[理学-物理学] 

基  金:This work was supported by the National K ey Research and Development Program of China(Grant No.2016 Y F B 0901405) the Science Fund for Creative Research Groups(No.51621062) the National Natural Science Foundation of China(Grant No.51806117,51236004) 

主  题:combined cooling heating and power systems(CCHP) energy-matching performance operation strategies comprehensive parameter energy saving performance 

摘      要:Although numerous studies have considered the two traditional operation strategies:following the electric load(FEL)and following the thermal load(FTL),for combined cooling,heating,and power(CCHP)systems in different case studies,there are limited theoretical studies on the quantification methods to assess the feasibility of these two strategies in different load demands ***,instead of a case study,we have undertaken a theoretical analysis of the suitable application scenarios for FEL and FTL strategies based on the energy-matching performance between systems provision and users *** compare the calculation models of energy saving rate(ESR)for FEL and FTL strategies in the left and right sub-regions of the energy-supply curve,a comprehensive parameter(^)that combines three inherently influential factors(off-design operation parameter,energy-matching parameter,and install capacity coefficient)is defined to determine the optimal installed capacity and feasibility of FEL or FTL strategies *** results indicate that greater value of x contribute to a better energy saving performance,and FEL strategy shows better performance than FTL in most load demands scenarios,and the optimal installed capacity occurs when the load demand points were located in different regions of the energy-supply ***,taking a hotel in Beijing as an example,the value of the optimal install capacity coefficient is 0.845 and the FEL strategy is also suggested,and compared to the maximum install capacity,the average values of the ESR on a typical summer day,transition season,and winter can be enhanced by 3.9%,8.8%,and 1.89%,respectively.