咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >A Sensitive and High-Throughpu... 收藏

A Sensitive and High-Throughput Flow Cytometry-Based Assay for Measuring Antibody Neutralization of Human Adenovirus Type 3

A Sensitive and High-Throughput Flow Cytometry-Based Assay for Measuring Antibody Neutralization of Human Adenovirus Type 3

作     者:Zhenwei Liu Xingui Tian Wenkuan Liu Yuting Xian Weilue Chen Rong Zhou Zhenwei Liu;Xingui Tian;Wenkuan Liu;Yuting Xian;Weilue Chen;Rong Zhou

作者机构:State Key Laboratory of Respiratory DiseaseNational Clinical Research Center for Respiratory DiseaseGuangzhou Institute of Respiratory HealthThe First Affiliated Hospital of Guangzhou Medical UniversityGuangzhou Medical UniversityGuangzhou 510000China 

出 版 物:《Virologica Sinica》 (中国病毒学(英文版))

年 卷 期:2021年第36卷第3期

页      面:537-544页

核心收录:

学科分类:1010[医学-医学技术(可授医学、理学学位)] 10[医学] 

基  金:supported by the National Science and Technology Major Project of China (2017ZX10103011-003, 2018ZX10102001) the National Natural Science Foundation of China (31570163) Guangzhou Science and Technology Program key projects (201803040004) 

主  题:Sensitive High-throughput Flow cytometry Neutralization Adenovirus 

摘      要:The assessment of neutralization activity is an important step in the evaluation of neutralizing antibodies (NAbs).The traditional methods for measuring the antibody neutralization of human adenovirus type 3 (HAd V-3) are the microneutralization (MN) assay,which has insufficient sensitivity,and the plaque reduction neutralization test (PRNT),which is not suitable for high-throughput ***,we describe the development of a flow cytometry-based neutralization(FCN) assay for measuring the neutralization of sera,cell culture supernatants,and chimeric antibodies against HAd V-3 on the basis of a recombinant HAd V-3 (r HAd V-3) construct expressing the enhanced green fluorescent protein (EGFP).For flow cytometry-based assays,the optimal cell confluence was determined as 90%,and the virus was titrated using the *** established FCN assay follows the percentage law and an optimal MOI of not less than 5 9 10~(-4)was determined by using a purified chimeric *** addition,comparison of the anti-HAd V-3 NAb titers of 72 human serum samples by the MN and FCN assays,showed that both assays correlated strongly with each *** FCN assay was an improvement over the MN assay because the observation period was reduced from 3 to 1 days and data analysis could be performed objectively and ***,the newly established FCN assay allows measurement of the neutralization activity of chimeric antibodies expressed in cell culture ***,this sensitive and highthroughput FCN assay is a useful alternative to the MN assay for measuring the antibody neutralization of HAd V-3 and for screening anti-HAd V-3 NAbs in cell culture supernatants.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分