咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Effect of osteoporosis and int... 收藏

Effect of osteoporosis and intervertebral disc degeneration on endplate cartilage injury in rats

Effect of osteoporosis and intervertebral disc degeneration on endplate cartilage injury in rats

作     者:Lei Wang Wei Cui Jean Pierre Kalal Tom Van Hoof Bao-Ge Liu 

作者机构:Department of OrthopaedicsBeijing Tiantan Hospital affiliated to Capital Medical University Department of NeurosurgeryUniversity HospitalUniversity of GhentBelgium Department of Human AnatomyEmbryologyHistology and Medical PhysicsUniversity of GhentBelgium 

出 版 物:《Asian Pacific Journal of Tropical Medicine》 (亚太热带医药杂志(英文版))

年 卷 期:2014年第7卷第10期

页      面:796-800页

核心收录:

学科分类:1002[医学-临床医学] 100210[医学-外科学(含:普外、骨外、泌尿外、胸心外、神外、整形、烧伤、野战外)] 100201[医学-内科学(含:心血管病、血液病、呼吸系病、消化系病、内分泌与代谢病、肾病、风湿病、传染病)] 10[医学] 

基  金:supported by National Science Foundation.Grant No.81171764 

主  题:Osteoporosis Intervertebral disc degeneration Vertebral bodies Cartilage endplate Damage 

摘      要:Objective:To investigate the effect of osteoporosis and intervertebral disc degeneration on the endplate cartilage injury in ***:A total of 48 female Sprague Dawley rats(3 months)were randomly divided into Groups A,B,C and D with 12 rats in each *** and intervertebral disc degeneration composite model,simple degeneration model and simple osteoporosis model were prepared in Groups A,B and C *** modeling,four rats of each group at 12th.18th and 24th week were sacrificed,Intervertebral height of cervical vertebra C6/C7 was ***-CT was used to image the endplate of cephalic and caudal cartilage at C6/C7 intervertebral *** area rate of C6 caudal and C7 cephalic cartilage endplate was calculated,and then C6/C7 intervertebral disc was routinely embedded and *** with safranin O to observe histological changes ***:At 12,18 and24 weeks,intervertebral disc height of C6/C7 were(0.58±0.09)mm,(0.53±0.04)mm and(0.04±0.06)mm in Group A rats,(0.55±0.05)mm,(0.52±0.07)mm and(0.07±0.05)mm in Group B *** 24th *** disc height of Group A rats was significantly lower than that of Group B rats(P0.05).At 12 and 18 weeks,the abraded rate of C6 caudal and C7 cephalic cartilage endplate in Group A rats were significantly higher than that in Groups B.C and D rats(P0.05).Microscopic observation of CT showed that ventral defects in C6caudal or C7 cephalic cartilage endplate in Groups A and B appeared after 12 weeks of modeling;obvious cracks were found in front of the C6 and C7 vertebral body,and cartilage defect shown the trend ofrepairingat 18 and 24 weeks a

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分