A Novel Tetraiodocadmate(Ⅱ) - PVC Membrane Electrode for the Potentiometric Determination of Cadmium(Ⅱ)

A Novel Tetraiodocadmate(Ⅱ)–PVC Membrane Electrode for the Potentiometric Determination of Cadmium(Ⅱ)

作     者:Fu Chang WANG Ya Qin CHAI Ruo YUAN 

作者机构:Chongqing Key Laboratory of Analytical Chemistry College of Chemistry and Chemical Engineering Southwest University Chongqing 400715 

出 版 物:《Chinese Chemical Letters》 (中国化学快报(英文版))

年 卷 期:2006年第17卷第7期

页      面:941-944页

核心收录:

学科分类:081704[工学-应用化学] 07[理学] 08[工学] 0817[工学-化学工程与技术] 0703[理学-化学] 070301[理学-无机化学] 

基  金:Thanks for the financial support of the Natural Science Foundation of Chongqing City (No. CSTC-2005 BB4100) the Southwest University Foundation (XSGX02) for the present work 

主  题:Tetraiodocadmate(Ⅱ) ion pair membrane electrode. 

摘      要:A novel tetraiodocadmate(Ⅱ)-selective membrane electrode consisting of tetraiodo-cadmate(Ⅱ)-rhodamin B ion pair (TICRhB) dispersed in a PVC matrix plasticized with 2-nitrophenyl octyl ether (o-NPOE) was prepared. The sensor demonstrated a near-Nernstian response for 1×10^-2 to 2×10^-6 mol/L cadmium (Ⅱ) at 25℃ with an anionic slope of 29.0. It revealed very good selectivity for Cd^2+ with negligible interference from many cations and anions, and could be used in a pH range of 3 to 6.