咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Ultrahigh-sensitive optical co... 收藏

Ultrahigh-sensitive optical coherence elastography

作     者:Yan Li Sucbei Moon Jason JChen Zhikai Zhu Zhongping Chen Yan Li;Sucbei Moon;Jason J.Chen;Zhikai Zhu;Zhongping Chen

作者机构:Beckman Laser InstituteUniversity of CaliforniaIrvineIrvineCA 92612USA Department of Biomedical EngineeringUniversity of CaliforniaIrvineIrvineCA 92617USA Department of PhysicsKookmin UniversitySeoul 02707South Korea 

出 版 物:《Light(Science & Applications)》 (光(科学与应用)(英文版))

年 卷 期:2020年第9卷第1期

页      面:1470-1479页

核心收录:

学科分类:0808[工学-电气工程] 070207[理学-光学] 0809[工学-电子科学与技术(可授工学、理学学位)] 07[理学] 08[工学] 0805[工学-材料科学与工程(可授工学、理学学位)] 0803[工学-光学工程] 0702[理学-物理学] 

基  金:National Institutes of Health(R01EY-026091,R01EY-028662,R01HL-125084,R01HL-127271) American Heart Association(18PRE34050021) the National Science Foundation(DGE-1839285) 

主  题:optical interferometer polarization 

摘      要:The phase stability of an optical coherence elastography(OCE)system is the key determining factor for achieving a precise elasticity measurement,and it can be affected by the signal-to-noise ratio(SNR),timing jitters in the signal acquisition process,and fluctuations in the optical path difference(OPD)between the sample and reference *** this study,we developed an OCE system based on swept-source optical coherence tomography(SS-OCT)with a common-path configuration(SS-OCECP).Our system has a phase stability of 4.2 mrad without external stabilization or extensive post-processing,such as *** phase stability allows us to detect a displacement as small as~300 pm.A common-path interferometer was incorporated by integrating a 3-mm wedged window into the SS-OCT system to provide intrinsic compensation for polarization and dispersion mismatch,as well as to minimize phase fluctuations caused by the OPD *** wedged window generates two reference signals that produce two OCT images,allowing for averaging to improve the ***,the electrical components are optimized to minimize the timing jitters and prevent edge collisions by adjusting the delays between the trigger,k-clock,and signal,utilizing a high-speed waveform digitizer,and incorporating a high-bandwidth balanced *** validated the SSOCECP performance in a tissue-mimicking phantom and an in vivo rabbit model,and the results demonstrated a significantly improved phase stability compared to that of the conventional *** the best of our knowledge,we demonstrated the first SS-OCECP system,which possesses high-phase stability and can be utilized to significantly improve the sensitivity of elastography.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分