咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Detection of DC series arc in ... 收藏

Detection of DC series arc in more electric aircraft power system based on optical spectrometry

作     者:Jun Jiang Mingxin Zhao Zhe Wen Chaohai Zhang Ricardo Albarracín 

作者机构:Center for More Electric Aircraft Power SystemNanjing University of Aeronautics and AstronauticsNanjing 211106People's Republic of China Departamento de Ingeniería EléctricaElectrónicaAutomática y Física AplicadaEscuela Técnica Superior de Ingeniería y Diseño IndustrialUniversidad Politécnica de MadridRonda de Valencia 328012 MadridSpain 

出 版 物:《High Voltage》 (高电压(英文))

年 卷 期:2020年第5卷第1期

页      面:24-29页

核心收录:

学科分类:080801[工学-电机与电器] 0808[工学-电气工程] 08[工学] 

基  金:This work was supported in part by the National Natural Science Foundation of China(grant no.51807088) the Natural Science Foundation of Jiangsu Province(BK20170786) the Fundamental Research Funds for the Central Universities(no.XCA17003-04) the Postgraduate Research and Practice Innovation Program of Jiangsu Province(no.SJCX18_0099) 

主  题:power system series 

摘      要:Series arcing faults have been recognised as a hazardous phenomenon in the power system of more electric aircraft(MEA),especially with the increasing voltage level and power *** of the electrical method,the optical method can be used as an approach to detect arc fault with the advantages of fast response and immunity to electromagnetic *** is the basis of optical arc detection to determine the distribution spectrum range of direct current(DC)arc *** at series arc optical detection in the MEA DC system,a DC series arc test platform was established to measure the series arc *** spectrum was disassembled though empirical mode decomposition to extract characteristic wavelengths of arc light and denoised by means of wavelet decomposition and reconstruction(wavelet transformation)to reduce equipment *** resolve the baseline drift,the baseline of the arc spectrum measured was calculated and corrected based on Savitzky−*** experimental results indicate that there are several series arc characteristic spectra of the MEA DC system,including 309.3 and 324.5 nm in the ultraviolet ***,the arc spectrum with different metals,copper and aluminium,were contrasted,indicating the arc spectral behaviour is related to the melting/boiling point and chemical properties of the anode *** measurement of the series arc spectrum makes it more effective to apply optical detection in the MEA discharging faults diagnosis.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分