咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Biomedical applications of Jon... 收藏

Biomedical applications of Jones-matrix tomography to polycrystalline films of biological fuids

作     者:V.A.Ushenko A.Yu.Sdobnov W.D.Mishalov A.V.Dubolazov O.V.Olar V.T.Bachinskyi A.G.Ushenko Yu.A.Ushenko O.Ya.Wanchuliak I.Meglinsk V.A.Ushenko;A.Yu.Sdobnov;W.D.Mishalov;A.V.Dubolazov;O.V.Olar;V.T.Bachinskyi;A.G.Ushenko;Yu.A.Ushenko;O.Ya.Wanchuliak;I.Meglinski

作者机构:Chernivtsi National University 2 Kotsiubynskyi St.Chernivtsi58012 Ukraine Faculty of Information Technology and Electrical Engineering University of OuluOulu 90570Finland Shupyk National Medical Academy of Postgraduate Education 9Dorogozhytska St.Kyiv04112 Ukraine Bukovinian State Medical University 3 Theatral Sq.Chernivtsi58000 Ukraine Interdisciplinary Laboratory of Biophotonics National Research Tomsk State University Tomsk634050 Russia Institute of Engineering Physics for Biomedicine(PhysBio)National Research Nuclear University"MEPhI"Moscow15409 Russia Aston Institute of Materials Research School of Engineering and Applied Science Aston UniversityBirminghamB47ETUK School of Life and Health SciencesAston University BirminghamB47ETUK 

出 版 物:《Journal of Innovative Optical Health Sciences》 (创新光学健康科学杂志(英文))

年 卷 期:2019年第12卷第6期

页      面:72-84页

核心收录:

学科分类:0831[工学-生物医学工程(可授工学、理学、医学学位)] 08[工学] 0836[工学-生物工程] 

基  金:support of the Academy of Finland(grant projects:311698) support of INFOTECH grant project,as well as the MEPhI Academic Excellence Project(Contract No.02.a03.21.0005) the National Research Tomsk State University Academic D.I.Mendeleev Fund Program 

主  题:Polarization Fourier optics and signal processing imaging systems medical and biological imnaging 

摘      要:Algorithms for reconstruction of linear and circular birefringence-dichroism of optically thin anisotropic biological layers are *** technique of Jones matrix tomography of poly-crystalline films of biological fuids of various human organs has been developed and experimentally *** coordinate distributions of phase and amplitude anisotropy of bile films and synovial fuid taken from the knee joint are determined and statistically ***(statistical moments of 3rd and 4th orders)of differential diagnostics of early stages of cholelithiasis and septic arthritis of the knee joint with excellent balanced accuracy were *** on the diagnostic fficiency of the Jones matrix tomography method for polyerystalline plasma(liver disease),urine(albuminuria)and cytological smears(cervical cancer)are presented.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分