咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >EVALUATION OF CIRRHOTIC LIVER ... 收藏

EVALUATION OF CIRRHOTIC LIVER WITH PERFUSION-WEIGHTED MAGNETIC RESONANCE IMAGING:A PRELIMINARY EXPERIMENTAL STUDY IN ANIMAL MODELS WITH HALF-LIVER CIRRHOSIS

EVALUATION OF CIRRHOTIC LIVER WITH PERFUSION-WEIGHTED MAGNETIC RESONANCE IMAGING:A PRELIMINARY EXPERIMENTAL STUDY IN ANIMAL MODELS WITH HALF-LIVER CIRRHOSIS

作     者:Zheng-han Yang Xiao-hua Ye Ye Tan Min Zhang Ming-zhu Zhou Jing-xia Xie Min Chen Cheng Zhou 

作者机构:Department of Radiology Beijing Hospital & the Fifth Clinical Medical School of Peking University Beijing 100730 Department of Radiology the Third Hospital of Peking University Beijing 100083 

出 版 物:《Chinese Medical Sciences Journal》 (中国医学科学杂志(英文版))

年 卷 期:2006年第21卷第4期

页      面:252-257页

核心收录:

学科分类:1002[医学-临床医学] 100201[医学-内科学(含:心血管病、血液病、呼吸系病、消化系病、内分泌与代谢病、肾病、风湿病、传染病)] 10[医学] 

主  题:liver cirrhosis animal model magnetic resonance imaging perfusion imaging 

摘      要:Objective To investigate the role of peffusion-weighted magnetic resonance imaging (MRI) in evaluation of cirrhotic fiver. Methods With a 4F catheter, 1% diluted carbon tetrachloride ( 1 ml/kg) was selectively injected into fight or left hepatic artery of 12 dogs fortnightly. The half fiver into which carbon tetrachloride was injected was called as study side (SS), while the other half fiver without carbon tetrachloride injection was called as study control side (SCS). Conventional and peffusion-weighted MRI were performed in every 4 weeks. Via a 4F catheter, 5ml gadolinium diethylentriamine pentaaceti acid (Gd-DTPA) dilution was injected into superior mesenteric artery at the 5th scan. The signal intensity-thne curves of SS, SCS, and portal vein were completed in MR workstation. The maximal relative signal increase ( MRSI), peak time ( tp), and slope of the curves were measured. Results On conventional MR images, no abnormalities of externality and signal intensity were observed in both SS and SCS of fiver at each stage. The mean tp, MP, SI, and slope of intensity-time curves in normal fiver were 10. 56 seconds, 1.01, and 10. 23 arbitrary unit (au)/s, respectively. Three parameters of curves didn't show obvious change in SCS of fiver at every stage. Abnormal perfusion curves occurred in SS of fiver at the 12th week after the 1st injection. The abnormality of perfusion curve in SS was more and more serious as the times of injection increased. The mean tp, IVlRSI, and slope intensity-time curves in SS of fiver were 19.45 seconds, 0. 43, and 3. 60 au/s respectively at the 24th week. Conclusion Perfusion-weighted imaging can potentially provide information about portal peffusion of hepatic parenchyma, and to some degree, reflect the severity of cirrhosis.

读者评论 与其他读者分享你的观点