Performance evaluation of BPM system in SSRF using PCA method
Performance evaluation of BPM system in SSRF using PCA method作者机构:Shanghai Institute of Applied Physics Chinese Academy of Sciences Shanghai Synchrotron Radiation Facility Chinese Academy of Sciences
出 版 物:《Chinese Physics C》 (中国物理C(英文版))
年 卷 期:2014年第38卷第7期
页 面:112-116页
核心收录:
学科分类:07[理学] 070202[理学-粒子物理与原子核物理] 0702[理学-物理学]
基 金:Supported by National Natural Science Foundation of China(11075198)
主 题:PCA MIA SVD storage ring SSRF
摘 要:The beam position monitor (BPM) system is of most importance in a light source. The capability of the BPM depends on the resolution of the system. The traditional standard deviation on the raw data method merely gives the upper limit of the resolution. Principal component analysis (PCA) had been introduced in the accelerator physics and it could be used to get rid of the actual signals. Beam related information was extracted before the evaluation of the BPM performance. A series of studies had been made in the Shanghai Synchrotron Radiation Facility (SSRF) and PCA was proved to be an effective and robust method in the performance evaluations of our BPM system.