咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Heating energy performance and... 收藏

Heating energy performance and part load ratio characteristics of boiler staging in an office building

作     者:Da Young LEE Byeong Mo SEO Yeo Beom YOON Sung Hyup HONG Jong Min CHOI Kwang Ho LEE 

作者机构:Graduate SchoolHanbat National UniversityDaejeon 305-719South Korea College of DesignNorth Carolina State University RaleighNC 27695-7701USA Department of Mechanical EngineeringHanbat National UniversityDaejeon 305-719South Korea Department of Architectural Engineering Hanbat National UniversityDaejeon 305-719South Korea 

出 版 物:《Frontiers in Energy》 (能源前沿(英文版))

年 卷 期:2019年第13卷第2期

页      面:339-353页

核心收录:

学科分类:0808[工学-电气工程] 08[工学] 0807[工学-动力工程及工程热物理] 

基  金:supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea the Human Resources Development of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Trade, Industry & Energy 

主  题:EnergyPlus boiler part load ratio gas con-sumption office building boiler staging 

摘      要:Commercial buildings account for significant portions of the total building energy in South Korea and thus a variety of research on the boiler operation related to heating energy in office buildings has been carried out thus far. However, most of the researches have been conducted on the boiler itself, i.e., the part load ratio characteristics and the corresponding gas energy consumption patterns are not analyzed in the existing studies. In this study, the part load ratio and the operating characteristics of gas boiler have been analyzed within an office building equipped with the conventional variable air volume system. In addition, the gas consumption among different boiler staging schemes has been comparatively analyzed. As a result, significant portions of total operating hours, heating load and energy consumption has been found to be in a part load ratio range of 0 through 40% and thus energy consumption is significantly affected by boiler efficiency at low part load conditions. This suggests that boiler operation at the part load is an important factor in commercial buildings. In addition, utilizing sequential boiler staging scheme can save a gas usage of about 7%. For annual heating energy saving, applying the sequential control boiler with a 3:7 proportion staging is considered to be the optimal control algorithm for maximum efficiency of boilers.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分