咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Primary prevention of sudden c... 收藏

Primary prevention of sudden cardiac death by implantable cardioverter-defibrillator therapy in Chinese patients with heart failure: a single-center experience

Primary prevention of sudden cardiac death by implantable cardioverter-defibrillator therapy in Chinese patients with heart failure: a single-center experience

作     者:CHEN Tai-bo CHENG Kang-an GAO Peng CHENG Zhong-wei FAN Jing-bo JIANG Xiu-chun FANG Quan 

作者机构:Department of Cardiology Peking Union Medical College Hospital Chinese Academy of Medical Sciences Beijing 100730China 

出 版 物:《Chinese Medical Journal》 (中华医学杂志(英文版))

年 卷 期:2010年第123卷第7期

页      面:848-851页

核心收录:

学科分类:0831[工学-生物医学工程(可授工学、理学、医学学位)] 1004[医学-公共卫生与预防医学(可授医学、理学学位)] 1002[医学-临床医学] 08[工学] 081101[工学-控制理论与控制工程] 0811[工学-控制科学与工程] 10[医学] 

主  题:implantable cardioverter-defibrillator primary prevention heart failure Chinese 

摘      要:Background An implantable cardioverter-defibrillator (ICD) has been suggested for heart failure patients for primary prevention of sudden cardiac death. However, few data have been reported on the application of ICD as primary prevention of sudden cardiac death in China. We evaluated the value of primary prevention ICD therapy in Chinese patients with heart *** Thirty-four patients at an average age of (60.2±13.7) years seen in Peking Union Medical College Hospital were treated with ICD implantation for primary prevention of sudden cardiac death from November 2005 to July 2009. Single-chamber ICDs were implanted in 16 (47.0%) cases, and dual-chamber or cardiac resynchronization therapy defibrillators in 18 (53.0%) cases. The patients had an average left ventricular ejection fraction of (26.9±5.5)% (11% to 35%), of which 18 (53.0%) patients had ischemic cardiomyopathy and 16 (47.0%) patients had non-ischemic cardiomyopathy. All patients were followed up at three months after the implantation and every six months thereafter or when prompted by an ICD *** There were five (14.7%) deaths, including two of heart failure and three with a non-cardiac course, during an average follow-up of (15.0±11.9) months. Forty-one ICD therapy events were recorded, including 19 (46.3%) appropriate ICD therapies in six patients and 22 (53.7%) inappropriate ICD therapies in four patients with single chamber leads. Inappropriate ICD therapies were mainly due to supraventricular tachyarrhythmias, especially atrial fibrillation. Patients with ischemic cardiomyopathy and non-ischemic cardiomyopathy did not differ in the incidence of either appropriate or inappropriate *** ICD for primary prevention of sudden cardiac death in China prevents patients from arrhythmia death. Relatively high incidence of inappropriate therapies highlights the importance of an atrial lead.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分