Research on Noise Control for Ventilators with Resonance

Research on Noise Control for Ventilators with Resonance

作     者:GUO Chu-wen SUN Fei-hong 

作者机构:College of Mechanical and Electrical Engineering China University of Mining & Technology Xuzhou Jiangsu 221008 China Xuzhou Institute of Architectural Technology Xuzhou Jiangsu 221008 China 

出 版 物:《Journal of China University of Mining and Technology》 (中国矿业大学学报(英文版))

年 卷 期:2006年第16卷第1期

页      面:25-27页

核心收录:

学科分类:12[管理学] 083002[工学-环境工程] 1204[管理学-公共管理] 120402[管理学-社会医学与卫生事业管理(可授管理学、医学学位)] 0830[工学-环境科学与工程(可授工学、理学、农学学位)] 081901[工学-采矿工程] 0819[工学-矿业工程] 08[工学] 0837[工学-安全科学与工程] 

主  题:Resonance noise ventilator noise control coalmine 

摘      要:A study was carried out to control the noise produced by the ventilators at the Luling coalmine, which had caused serious noise pollution to the residents living around the mine for a long time. The main noise source was found to be the dynamic noise at the outlet of the diffuser. The frequency of its peak value was 250 Hz. A special brick with a resonant frequency of 250 Hz was designed to eliminate this noise. The diffusion of a lower frequency noise has been successfully controlled by the installation of a noise-eliminating tower above the diffuser outlet. The detection results show that the noise in the nearby residential area has been lowered to an average 55.3dB(A) in the daytime from 69.8dB(A) and to 48.4dB(A) at night from 65.8dB(A).