A critical quality parameter in quantitative fused-core chromatography: The injection volume

A critical quality parameter in quantitative fused-core chromatography: The injection volume

作     者:Jente Boonen Matthias D’hondt Lieselotte Veryser Kathelijne Peremans Christian Burvenich Bart De Spiegeleer 

作者机构:Drug Quality and Registration (DruQuaR) Group Faculty of Pharmaceutical Sciences Ghent University Department of Veterinary Medical Imaging and Small Animal Orthopaedics Faculty of Veterinary Medicine Ghent University Department of Comparative Physiology and Biometrics Faculty of Veterinary Medicine Ghent University 

出 版 物:《Journal of Pharmaceutical Analysis》 (药物分析学报(英文版))

年 卷 期:2013年第3卷第5期

页      面:330-334页

学科分类:1007[医学-药学(可授医学、理学学位)] 100704[医学-药物分析学] 10[医学] 

基  金:funded by the "Institute for the Promotion of Innovation through Science and Technology in Flanders (IWT-Vlaanderen)’’ to Jente Boonen(No.091257) and to Matthias D’Hondt(No.101529) 

主  题:Spilanthol Fused-core (pore-shell,Halo) HPLC Superficially porousparticles (SPP) Injection volume ToPical patch Critical quality method-attribute (CQA) 

摘      要:As part of the method development, the injection volume as a critical quality attribute in fast fused-core chromatography was evaluated. Spilanthol, a pharmaceutically interesting N- alkylamide currently under investigation in our laboratory, was chosen as the model compound. Spilanthol was dissolved in both PBS and MeOH/H20 (70/30, v/v) and subsequently analyzed using a fused-core system hereby selecting five chromatographic characteristics (retention time, area, height, theoretical plates and symmetry factor) as responses. We demonstrated that the injection volume significantly influenced both the qualitative and quantitative performance of fused-core chromatography, a phenomenon which is confounded with the nature of the used sample solvent. From 2 ~tL up to 100 laL injection volume with PBS as solvent, the symmetry factor decreased favorably by 20%. Moreover, the theoretical plates and the quantitative parameters (area and height) increased up to 30%. On the contrary, in this injection volume range, the theoretical plates for the methanol-based samples decreased by more than 60%, while the symmetry factor increased and the height decreased, both by 30%. The injection volume is thus a critical and often overlooked parameter in fused-core method description and validation.