文献详情 >A Study of Real-time Peak Oxyg... 收藏

A Study of Real-time Peak Oxygen Consumption and Six-minute Walk Test

A Study of Real-time Peak Oxygen Consumption and Six-minute Walk Test

作     者:Guolin Zhang Lan Guo He Li Jingzhuang Mai Zhi Liu Sixian Huang 

作者机构:Guangdong Cardiovascular Institute Guangdong Provincial People's Hospital Guangzhou 510080 China 

出 版 物:《South China Journal of Cardiology》 (岭南心血管病杂志(英文版))

年 卷 期:2007年第8卷第4期

页      面:179-182页

学科分类:12[管理学] 1204[管理学-公共管理] 120402[管理学-社会医学与卫生事业管理(可授管理学、医学学位)] 1004[医学-公共卫生与预防医学(可授医学、理学学位)] 10[医学] 

主  题:six-minute walk test oxygen consumption(PVO2) cardiopulmonary function 

摘      要:Objectives To assess the relationship between peak oxygen consumption (PVO2) and the ambulation distance in six-minute walk test (6MWT)among the healthy subjects. Methods The 51 healthy subjects were recruited for the six-minute walk test. Data of pulmonary gas exchange breath by breath, such as VO2 , VCO2 were real-time measured with wireless remote sensing K4B2, so to study the relationship between peak oxygen uptake and the ambulation distance. Results It was noticed that there was a positive linear correlation between the ambulation distance and PVO2 ( r =0. 619, P 〈0. 001 ) in six-minute walk test. The regression equation was set up ( VO2/kg =0. 05D -6. 331, P 〈 0. 001 ). PVO2 〉 PVCO2 ,R 〈 1 were found,which suggested that 6MWT was a test below anaerobic threshold. Conclusions There was a closely positive linear correlation between the ambulation distance and PVO2, which is safety, convenient and valuable for the evaluation of cardiopulmonary function and the treatment of cardiopulmonary rehabilitation.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分