Alignment technology of heavy ion medicalmachine

作     者:Wenjun Chen Yaqing Yang Guozhu Cai Zhiguo Cui Xiaorong Zhu Shaoming Wang 

作者机构:Institute of Modern PhysicsChinese Academy of SciencesLanzhou 730000China University of Chinese Academy of SciencesBeijing 100049China Huizhou Research Center of Ion ScienceHuizhou 516000China 

出 版 物:《Radiation Detection Technology and Methods》 (辐射探测技术与方法(英文))

年 卷 期:2019年第3卷第2期

页      面:37-43页

学科分类:07[理学] 070202[理学-粒子物理与原子核物理] 0702[理学-物理学] 

主  题:Heavy ion accelerator Three-dimensional control network Laser tracker Alignment Fiducialization 

摘      要:Background Heavy ion medical machine(HIMM)is built by the Institute of Modern Physics,Chinese Academy of Sciences,with a high-energy beam transport line with a height of 18 m,and its complex space mounting structure increases the difficulty of installation and *** The aim of this paper is to provide methods to install all accelerator components efficiently and to ensure that the alignment accuracies of all installed components are within the designed *** We accomplished the fiducialization and pre-alignment of complex modules by combining the laser tracker and the alignment *** analyzing various elements that affect the accuracy of alignment,a method of alignment for high-energy beam transport line was proposed based on high-precision three-dimensional control *** All components have been installed and aligned in a short time,alignment position accuracy of magnets is less than 0.1 mm,and the treatment components alignment accuracy is no more than 0.4 *** On the basis of error analysis,all alignment results are better than the required precisions,and all of these guaranteed the successful operation of HIMM.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分