Marginal discrepancy and microleakage in crown-copings fabricated by three CAD/CAM systems: An <i>in vitro</i>study
Marginal discrepancy and microleakage in crown-copings fabricated by three CAD/CAM systems: An <i>in vitro</i>study作者机构:Department of Oral Pathology Faculty of Dentistry University of Concepción Concepción Chile Department of Public Health School of Medicine University of Concepción Concepción Chile Department of Restorative Dentistry Faculty of Dentistry University of Concepción Concepción Chile
出 版 物:《Open Journal of Stomatology》 (口腔学期刊(英文))
年 卷 期:2012年第2卷第3期
页 面:163-169页
学科分类:1002[医学-临床医学] 100214[医学-肿瘤学] 10[医学]
主 题:CAD/CAM Copings Microleakage Marginal Discrepancy Panavia F.2
摘 要:The purpose of this study was to evaluate and compare the microleakage and marginal discrepancy of ceramic crown-copings fabricated by three different CAD/CAM systems. Material and methods: Thirty extracted premolars were prepared for complete all-ceramic crowns with: total convergence 10-degree, 2 mm occlusal reduction, 4.5 mm height, 1.3 mm circular reduction and chamfer marginal preparation. They were divided into three groups and each group (n = 10) received a ceramic crown-coping fabricated by one of three CAD/CAM systems: Procera, KaVo Everest and Cerec inLab. The copings were cemented with Panavia F 2.0. After thermal cycling, the teeth were immersed in 2% basic fuchsine dye for 24 hours. Microleakage was scored using a five-point scale and evaluated under a stereomicroscope at ×18. Marginal discrepancies were assessed with scanning electronic microscope at ×150, with measurements at 50 different points. Data were subjected to a chisquare test, Kolmogorov-Smirnov test and using Rho Spearman’s correlation test (P 0.05). No significant differences were found in marginal discrepancies for the Procera (62.58 ± 8.98 μm) and KaVo Everest systems (65.54 ± 18.56 μm), (P = 0.941). Significant differences were found for Cerec inLab (132.18 ± 27.75 μm) compared with Procera and KaVo Everest (P = 0.0001). No correlation between the marginal discrepancies and microleakage for the three CAD/CAM crown-copings systems. Conclusions: Cerec inLab CAD/CAM crown-copings showed significantly higher values for microleakage and marginal discrepancy in comparison with Procera and KaVo Everest CAD/CAM crown-copings.