Electron temperature diagnostics of aluminium plasma in a z-pinch experiment at the "QiangGuang-1" facility

Electron temperature diagnostics of aluminium plasma in a z-pinch experiment at the "QiangGuang-1" facility

作     者:李沫 吴坚 王亮平 吴刚 韩娟娟 郭宁 邱孟通 

作者机构:Northwest Institute of Nuclear Technology 

出 版 物:《Chinese Physics B》 (中国物理B(英文版))

年 卷 期:2012年第21卷第12期

页      面:322-326页

核心收录:

学科分类:07[理学] 0805[工学-材料科学与工程(可授工学、理学学位)] 070204[理学-等离子体物理] 0704[理学-天文学] 0702[理学-物理学] 

基  金:Project supported by the Young Scientists Fund of the National Natural Science Foundation of China(Grant No.10905047) 

主  题:electron temperature continuum curved crystal spectrometer z-pinch 

摘      要:Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several "bright spots" indicate electron temperatures between (450 eV- 520 eV) ± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV±30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a - 1 MA facility.