咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Therapeutic efficacy and stent... 收藏

Therapeutic efficacy and stent patency of transhepatic portal vein stenting after surgery

Therapeutic efficacy and stent patency of transhepatic portal vein stenting after surgery

作     者:Ung Bae Jeon Chang Won Kim Tae Un Kim Ki Seok Choo Joo Yeon Jang Kyung Jin Nam Chong Woo Chu Je Ho Ryu 

作者机构:Department of Radiology Pusan National University Yangsan Hospital Department of Radiology Medical Research Institute Pusan National University School of Medicine and Research Institute for Convergence of Biomedical Science and Technology Pusan National University Hospital Department of Surgery Pusan National University Yangsan Hospital 

出 版 物:《World Journal of Gastroenterology》 (世界胃肠病学杂志(英文版))

年 卷 期:2016年第22卷第44期

页      面:9822-9828页

核心收录:

学科分类:1002[医学-临床医学] 100210[医学-外科学(含:普外、骨外、泌尿外、胸心外、神外、整形、烧伤、野战外)] 10[医学] 

主  题:Liver Vein Stent Computed tomography Surveillance Efficace 

摘      要:AIM To evaluate portal vein(PV) stenosis and stent patency after hepatobiliary and pancreatic surgery, using abdominal computed tomography(CT).METHODS Percutaneous portal venous stenting was attempted in 22 patients with significant PV stenosis( 50%)-after hepatobiliary or pancreatic surgery- diagnosed by abdominal CT. Stents were placed in various stenotic lesions after percutaneous transhepatic portography. Pressure gradient across the stenotic segment was measured in 14 patients. Stents were placed when the pressure gradient across the stenotic segment was 5 mm Hg or PV stenosis was 50%, as observed on transhepatic portography. Patients underwent followup abdominal CT and technical and clinical success, complications, and stent patency were *** Stent placement was successful in 21 patients(technical success rate: 95.5%). Stents were positioned through the main PV and superior mesenteric vein(n = 13), main PV(n = 2), right and main PV(n = 1), left and main PV(n = 4), or main PV and splenic vein(n = 1). Patients showed no complications after stent placement. The time between procedure and final follow-up CT was 41-761 d(mean: 374.5 d). Twenty stents remained patent during the entire follow-up. Stent obstruction-caused by invasion of the PV stent by a recurrent tumor- was observed in 1 patient in a follow-up CT performed after 155 d after the procedure. The cumulative stent patency rate was 95.7%. Small in-stent low-density areas were found in 11(55%) patients; however, during successive follow-up CT, the extent of these areas had *** Percutaneous transhepatic stent placement can be safe and effective in cases of PV stenosis after hepatobiliary and pancreatic surgery. Stents show excellent patency in follow-up abdominal CT, despite development of small in-stent low-density areas.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分