APPLICATION OF HIGH-RESOLUTION MAGNETIC METHOD AND GRADIENT METHOD TO LOCATE ABANDONED BRINE-WELLS IN HUTCHINSON, KANSAS, U.S.A.

APPLICATION OF HIGH-RESOLUTION MAGNETIC METHOD AND GRADIENT METHOD TO LOCATE ABANDONED BRINE-WELLS IN HUTCHINSON, KANSAS, U.S.A.

作     者:CHEN Chao XIA Jianghai XIA Sihao David Laflen Stephen L. Williams 

作者机构:The China University of Geosciences Wuhan 430074 China The University of Kansas Lawrence Kansas USA The City of Hutchinson Kansas USA 

出 版 物:《工程地球物理学报》 (Chinese Journal of Engineering Geophysics)

年 卷 期:2004年第1卷第1期

页      面:17-25页

学科分类:081801[工学-矿产普查与勘探] 081802[工学-地球探测与信息技术] 08[工学] 0818[工学-地质资源与地质工程] 

基  金:美国联邦政府资助项目 

主  题:High resolution magnetic method Magnetic gradient method Brine Well 

摘      要:After successfully locating one abandoned brine well by an electromagnetic method during testing in 2001 and five abandoned brine wells by a high resolution magnetic method during 2002, a high resolution magnetic method was again proposed to search for wells in 2003 when a second sensor was employed to acquire data for calculating the pseudo vertical gradient of magnetic fields. Total area surveyed in 2003 was 1,024,000 ft 2, which was divided into grids with an average size of 10,000 ft 2 and distributed across eight different sites. Magnetic anomalies and their vertical gradients from known brine wells were first recorded as signatures to identify anomalies caused by possible buried brine wells. Of fifty one verified anomalies, thirty one anomalies were due to wells buried at depths from 0 to 8.5 ft: twenty one 6 to 9 inch abandoned brine wells, seven 1.5 to 3 inch probable water wells, one 16 inch dewatering well for a construction site at a depth of 3 ft, and two 4 inch wells on the ground surface. Approximate monopole shaped anomalies were observed from all these wells after data corrections. However, the range of amplitudes of magnetic anomalies from 7,000 to 28,000 nT from these abandoned brine wells was measured. This range of anomalies is mainly due to the thickness and depth of buried wells. Anomaly amplitudes from 1.5 to 3 inch wells are 4,000 to 8,000 nT and linearly correlate with the buried depth. One 3 inch well that caused an anomaly of 13,000 nT could be the inner pipe of a brine well. Gradient anomalies are roughly in a range of 100 to 200 nT/inch for 1.5 to 3 inch wells and 200 to 300 nT/inch for brine *** indicated by the potential field theory, gradient data possess higher horizontal resolution than the magnetic field itself. Gradient data provide valuable assistance in determining horizontal locations of anomaly sources for excavation. In practice, however, improvement in the horizontal resolution is limited by survey line spacing. If only

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分