咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Assessment of cortical bone mi... 收藏

Assessment of cortical bone microdamage following insertion of microimplants using optical coherence tomography: a preliminary study

使用光学相干成像技术对皮质骨植入微种植体产生微创的评估(英文)

作     者:Hemanth Tumkur LAKSHMIKANTHA Naresh Kumar RAVICHANDRAN Mansik JEON Jeehyun KIM Hyo-sang PARK 

作者机构:Department of Orthodontics School of Dentistry Kyungpook National University School of Electronics Engineering College of IT Engineering Kyungpook National University 

出 版 物:《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 (浙江大学学报(英文版)B辑(生物医学与生物技术))

年 卷 期:2018年第19卷第11期

页      面:818-828页

核心收录:

学科分类:1003[医学-口腔医学] 100302[医学-口腔临床医学] 10[医学] 

基  金:Project supported by the BK21 Plus Project Funded by the Ministry of Education,Korea(No.21A20131600011) the Industrial Infrastructure Program of Laser Industry Support Funded by the Ministry of Trade,Industry & Energy,Korea(No.N0000598) 

主  题:Optical coherence tomography Microimplant Cortical bone Micro-computed tomography 

摘      要:Objectives: The study was done to evaluate the efficacy of optical coherence tomography (OCT), to detect and analyze the microdamage occurring around the microimplant immediately following its placement, and to compare the findings with micro-computed tomography (IJCT) images of the samples to validate the result of the present study. Methods: Microimplants were inserted into bovine bone samples. Images of the samples were obtained using OCT and μCT. Visual comparisons of the images were made to evaluate whether anatomical details and microdamage induced by microimplant insertion were accurately revealed by OCT. Results: The surface of the cortical bone with its anatomical variations is visualized on the OCT images. Microdamage occurring on the surface of the cortical bone around the microimplant can be appreciated in OCT images. The resulting OCT images were compared with the μCT images. A high correlation regarding the visualization of individual microcracks was observed. The depth penetration of OCT is limited when compared to μCT. Conclusions: OCT in the present study was able to generate high-resolution images of the microdamage occurring around the microimplant. Image quality at the surface of the cortical bone is above par when compared with μCT imaging, because of the inherent high contrast and high-resolution quality of OCT systems. Improvements in the imaging depth and development of intraoral sensors are vital for developing a real-time imaging system and integrating the system into orthodontic practice.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分