咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Comparative study on CO_2 corr... 收藏

Comparative study on CO_2 corrosion behavior of N80,P110,X52 and 13Cr pipe lines in simulated stratum water

Comparative study on CO_2 corrosion behavior of N80,P110,X52 and 13Cr pipe lines in simulated stratum water

作     者:CAI YiDong1,GUO PengChao1,LIU DaMeng1,CHEN ShiYu2 & LIU JunLai3 1 School of Energy Resources,China University of Geosciences,Beijing 100083,China 2 School of Materials Science and Engineering,University of Science and Technology Beijing,Beijing 100083,China 3 School of Earth Sciences and Resources,China University of Geosciences,Beijing 100083,China 

作者机构:School of Energy Resources China University of Geosciences Beijing China School of Materials Science and Engineering University of Science and Technology Beijing Beijing China School of Earth Sciences and Resources China University of Geosciences Beijing China 

出 版 物:《Science China(Technological Sciences)》 (中国科学(技术科学英文版))

年 卷 期:2010年第53卷第9期

页      面:2342-2349页

核心收录:

学科分类:080503[工学-材料加工工程] 08[工学] 0805[工学-材料科学与工程(可授工学、理学学位)] 

基  金:supported by the Daqing Oilfield Limited Company of PetroChina (Grant No. DQYT-0404003-2008-JS-963) 

主  题:CO2 corrosion pipe lines weight loss SEM EDS 

摘      要:To better understand the carbon dioxide (CO2) corrosion behavior of carbon steel and its influence on petroleum development (including drilling,production and transportation) in the Daqing Oilfield,CO2 corrosion behaviors of N80,P110,X52 and 13Cr pipe lines in simulated solution at high temperature and high pressure condition are investigated by dynamic corrosion experiments,scanning electron microscope (SEM) and energy dispersive X-ray spectroscopy (EDS) *** show that the corrosion rate of all pipe lines increases quickly when CO2 partial pressure increases from 0.5 to 1.5 MPa,but it slows down when CO2 partial pressure further increases from 1.5 to 4.5 MPa,during which localized corrosion is *** the experimental temperature ranges from 60 to 120°C,localized corrosion *** corrosion rate of all pipe lines decreases sharply when the temperature changes from 60 to 100°C,and it becomes stable after the temperature is higher than 100°*** the flow rate is in the range of 0–1.5 m/s,the corrosion rate of sample X52 remains unchanged,but localized corrosion gradually becomes very serious when the flow rate further *** analyzing the corrosion product scales of sample 13Cr,some remarkable phenomena are *** the temperature range of 60–100°C,the corrosion product scales are loose and thick,but become very compact when the temperature increases above 100°*** the later case,localized corrosion is *** main components of the corrosion product scales are FeCO3 and Cr2O3.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分