咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Introduction to investigations... 收藏

Introduction to investigations of the negative corona and EHD flow in gaseous two-phase fluids

Introduction to investigations of the negative corona and EHD flow in gaseous two-phase fluids

作     者:Jerzy MIZERACZYK Artur BERENDT 

作者机构:Department of Marine ElectronicsGdynia Maritime University Institute of Fluid Flow MachineryPolish Academy of Sciences 

出 版 物:《Plasma Science and Technology》 (等离子体科学和技术(英文版))

年 卷 期:2018年第20卷第5期

页      面:147-156页

核心收录:

学科分类:080704[工学-流体机械及工程] 08[工学] 0807[工学-动力工程及工程热物理] 0805[工学-材料科学与工程(可授工学、理学学位)] 0702[理学-物理学] 

基  金:supported by the National Science Centre(Grant No.UMO-2013/09/B/ST8/02054) 

主  题:DC negative corona discharge Trichel pulses gaseous two-phase flow air withsuspended particle flow ESP EHD 

摘      要:Research interests have recently been directed towards electrical discharges in multi-phase environments.Natural electrical discharges,such as lightning and coronas,occur in the Earth's atmosphere,which is actually a mixture of gaseous phase(air) and suspended solid and liquid particulate matters(PMs).An example of an anthropogenic gaseous multi-phase environment is the flow of flue gas through electrostatic precipitators(ESPs),which are generally regarded as a mixture of a post-combustion gas with solid PM and microdroplets suspended in it.Electrical discharges in multi-phase environments,the knowledge of which is scarce,are becoming an attractive research subject,offering a wide variety of possible discharges and multi-phase environments to be studied.This paper is an introduction to electrical discharges in multi-phase environments.It is focused on DC negative coronas and accompanying electrohydrodynamic(EHD) flows in a gaseous two-phase fluid formed by air(a gaseous phase) and solid PM(a solid phase),run under laboratory conditions.The introduction is based on a review of the relevant literature.Two cases will be considered:the first case is of a gaseous two-phase fluid,initially motionless in a closed chamber before being subjected to a negative corona(with the needle-toplate electrode arrangement),which afterwards induces an EHD flow in the chamber,and the second,of a gaseous two-phase fluid flowing transversely with respect to the needle-to-plate electrode axis along a chamber with a corona discharge running between the electrodes.This review-based introductory paper should be of interest to theoretical researchers and modellers in the field of negative corona discharges in single-or two-phase fluids,and for engineers who work on designing EHD devices(such as ESPs,EHD pumps,and smoke detectors).

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分