Optimal Operation of Turbo Blowers Serially Connected Using Inlet Vanes
Optimal Operation of Turbo Blowers Serially Connected Using Inlet Vanes作者机构:Plant Research DivisionKorea Institute of Construction Technology1190 IIsanseo-GuGoyang-Si411-712Korea
出 版 物:《Journal of Thermal Science》 (热科学学报(英文版))
年 卷 期:2011年第20卷第1期
页 面:26-31页
核心收录:
学科分类:080704[工学-流体机械及工程] 08[工学] 0807[工学-动力工程及工程热物理]
主 题:Turbo Blower Inlet Vane Refuse Collection System Efficiency Numerical Simulation
摘 要:Optimal operation of the turbo blowers having an inlet vane has been studied to understand the blowers operating *** analyze three-dimensional flow field in the turbo blowers serially connected,general analysis code,CFX,is introduced in the present *** turbulence model is employed to estimate the eddy *** the numerical analysis,it is found that the flow rates of the turbo blowers can be controlled at the vane angle between 90 (full open condition) degrees and 60 degrees effectively,because pressure loss rapidly increases below 60 degree of a vane *** also has almost the same values from 90 degrees to 60 degrees of a vane *** is noted that the distorted inlet velocity generated in the small vane angle makes performance deterioration of the turbo blowers due to the local leading edge separation and the following non-uniform blade loading.