Inter-Calibration Between Plasma Instruments Onboard DEMETER

Inter-Calibration Between Plasma Instruments Onboard DEMETER

作     者:Maha S.QUASSIM 

作者机构:National Research Institute of Astronomy and GeophysicsHelwan 11421CairoEgypt 

出 版 物:《Plasma Science and Technology》 (等离子体科学和技术(英文版))

年 卷 期:2008年第10卷第5期

页      面:539-545页

核心收录:

学科分类:070802[理学-空间物理学] 07[理学] 0708[理学-地球物理学] 

基  金:This work is undertaken in CETP  Paris and supported in part by CNR.S-France 

主  题:plasma analyser satellite plasma observation ion density measuring 

摘      要:The in-situ measurements of the ionospheric plasma that we use come from two instruments of the scientific payload of the satellite DEMETER; the plasma analyser IAP (Instrument d'analyse du plasma) and the Langmuir probe ISL (Instrument Sonde de Langmuir). DEMETER is a micro-satellite realized by the CNES(Centre National d'Etudes Spatiales, France) with a principal objective to seek a possible influence of the seismic activity on the electromagnetic waves in the ionosphere and on the ionospheric plasma. The satellite was placed on June 29, 2004, in a circular and quasi helio-synchronous orbit at -710 km altitude. The experiments function primarily at mid-latitudes (from +60° to -60°). The IAP data were analysed to deduce the ion population (densities of the dominant ions, i.e. generally O^+, H^+ and He^+) therefore the total ion density. The use of data IAP thus requires some precaution to make sure that the electric equilibrium conditions of the satellite, such as the satellite potential (Фsat), are obtained during the treatment of routine, does not induce an error of measurement. When this potential is negative, the minority light ions H^+ and He^+ can be measured in a reliable way when their proportion is above 3% to 5% of that of O^+. The critical limitation is: under certain conditions, the satellite potential becomes positive and reach a value about -0.5 V so that it becomes impossible to measure H^+ ions. This is likely to involve a significant error on the composition and the density of the plasma. Therefore we carried out a calibration to estimate the missing density. The ISL experiment (Langmuir probe) provided the collected current/polarized tension characteristics of a cylindrical probe from which both electron density Ne and temperature Te were obtained. In some situations it is necessary to examine the accuracy of the electron density using another technique, for instance the high frequency (HF) spectrogram, provided by ICE (instrument champ electrique

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分