Excitation-Contraction Coupling Time is More Sensitive in Evaluating Cardiac Systolic Function
Excitation-Contraction Coupling Time is More Sensitive in Evaluating Cardiac Systolic Function作者机构:Department of Cardiology and Institute of Vascular Medicine Peking University Third Hospital Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides Ministry of Health Key Laboratory of Molecular Cardiovascular Science Ministry of Education Beijing Key Laboratory of Cardiovascular Receptors Research Beijing 100191 China State Key Laboratory of Membrane Biology College of Life Sciences Peking University Beijing 100871 China
出 版 物:《Chinese Medical Journal》 (中华医学杂志(英文版))
年 卷 期:2018年第131卷第15期
页 面:1834-1839页
核心收录:
学科分类:1305[艺术学-设计学(可授艺术学、工学学位)] 12[管理学] 1204[管理学-公共管理] 13[艺术学] 08[工学] 081303[工学-城市规划与设计(含:风景园林规划与设计)] 0813[工学-建筑学] 0833[工学-城乡规划学] 083302[工学-城乡规划与设计]
主 题:Excitation-Contraction Couplings Heart Failure Left Ventricular Dysfunction
摘 要:Background: Pressure overload-induced myocardial hypertrophy is a key step leading to heart failure. Previous cellular and animal studies demonstrated that deteriorated excitation-contraction coupling occurs as early as the compensated stage of hypertrophy before the global decrease in left ventricular ejection fraction (LVEF). This study was to evaluate the cardiac electromechanical coupling time in evaluating cardiac systolic function in the early stage of heart failure. Methods: Twenty-six patients with Stage B heart failure (SBHF) and 31 healthy controls (CONs) were enrolled in this study. M-mode echocardiography was performed to measure LVEF. Tissue Doppler imaging (TDI) combined with electrocardiography (ECG) was used to measure cardiac electromechanical coupling time. Results: There was no significant difference in LVEF between SBHF patients and CONs (64.23 ± 8.91% vs. 64.52 ± 5.90%; P= 0.886). However, all four electromechanical coupling time courses (Qsb: onset of Q wave on ECG to beginning of S wave on TDI, Qst: onset of Q wave on ECG to top of S wave on TDI, Rsb: top of R wave on ECG to beginning orS wave on TDI, and Rst: top of R wave on ECG to top orS wave on TDI) of SBHF patients were significantly longer than those of CONs (Qsb: 119.19 ± 35.68 ms vs. 80.30 ± 14.81 ms, P 〈 0.001 ; Qst: 165.42 ± 60.93 ms vs. 129.04 ± 16.97 ms, P = 0.006; Rsb: 82.43 ± 33.66 ms vs. 48.30 ± 15.18 ms, P 〈 0.001; and Rst: 122.37 ± 36.66 ins vs. 93.25 ± 16.72 ms, P = 0.001 ), and the Qsb, Rsb, and Rst time showed a significantly higher sensitivity than LVEF (Rst: P =0.032; Rsb: P = 0.003; and Qsb: P = 0.004). Conclusions: The cardiac electromechanical coupling time is more sensitive than LVEF in evaluating cardiac systolic function.