Position-sensitive plastic scintillator detector with WLS-fiber readout

Position-sensitive plastic scintillator detector with WLS-fiber readout

作     者:Jia-Ning Dong Yun-Long Zhang Zhi-Yong Zhang Dong Liu Zi-Zong Xu Xiao-Lian Wang Shu-Bin Liu 

作者机构:State Key Laboratory of Particle Detection and ElectronicsUniversity of Science and Technology of China Department of PhysicsUniversity of Science and Technology of China Department of Modern PhysicsUniversity of Science and Technology of China 

出 版 物:《Nuclear Science and Techniques》 (核技术(英文))

年 卷 期:2018年第29卷第8期

页      面:186-192页

核心收录:

学科分类:082704[工学-辐射防护及环境保护] 08[工学] 0827[工学-核科学与技术] 

基  金:supported by the Strategic Priority Research Program on Space Science of Chinese Academy of Sciences(No.XDA04070900) 

主  题:闪烁器 纤维结 位置 塑料 敏感 读出 WLS 光电倍增管 

摘      要:In this paper,the design,construction,simulation,and performance of a position-sensitive plastic scintillator detector are *** readout of the detector uses wavelength-shifting fibers coupled with multi-anode photomultipliers(PMTs) for the x-and *** calibrating the multi-anode PMTs,a two-dimensional projection image of the square scintillator telescope hit by cosmic muons is *** performing a cosmic test with the Micromegas telescope,the position resolution of the detector was determined to reach approximately8.6 mm,which is close to the value obtained in physical simulation.