文献详情 >A scintillator detector for be... 收藏

A scintillator detector for beam tuning of low-energy single electron accelerator

作     者:Yu-lan Li Yun-ting Gu Yu-guang Xie Jun-hui Yue Jun-guang Lv Shun-li Niu Shi-lun Pei Feng Shi Ling-da Yu Hang Zhao Wen-qi Yan Pin Lv Zhi-yuan Peng Geng-lan Li 

作者机构:Guangxi UniversityNanning 530004GuangxiChina Institute of High Energy PhysicsBeijing 100049China State Key Laboratory of Particle Detection and ElectronicsBeijing 100049China University of Chinese Academy of SciencesBeijing 100049China 

出 版 物:《Radiation Detection Technology and Methods》 (辐射探测技术与方法(英文))

年 卷 期:2017年第1卷第1期

页      面:29-39页

学科分类:07[理学] 070202[理学-粒子物理与原子核物理] 0702[理学-物理学] 

基  金:This work is also supported byNationalNatural Science Foundation of China(10565004) We acknowledge the support and cooperation of Hainan Zhanchuang Photonics Technology Co.,Ltd and Anderson Superconducting RF Accelerator Technology INC.We thank the members of the Beijing Test Beam Facility(BTBF)for their help 

主  题:Beam tuning Single electron beam PMT Plastic scintillator Slit 

摘      要:Purpose Nine scintillator detectors were developed for beam tuning of low-energy single electron accelerator instead of the picoammeter and Faraday cup,both of which will be insensitive to the weak-current beam lower than *** The detectors are based on plastic scintillator and photomultiplier tube(PMT)and the beam is 100 Hz pulsed electrons in the energy range of 0.1 to *** beam flux was tuned from about 107 to quasi-single electron for each bunch according to the measurement results of these detectors installed along the beam pipe and after *** order to determine the number of electrons in a bunch,the gains of each PMT were finely calibrated,and the energy response of each detector was calibrated with 207Bi radioactive ***,the deposited energy in the plastic scintillator,the electron detection efficiency and light collection efficiency,as a function of electron incident energy,were also simulated in detail by *** Nine detectors worked well at a gain of 0.6×10^(6) after installation in the beam pipe,and the number of electrons in a bunch could be measured at each detector *** single electron peak was seen when the beam reached the final *** The commissioning result shows that the beam was tuned to quasi-single electron level successfully and the scintillator detector is an effective method to measure the weak-current beam lower than picoampere.