咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Study of linearity of LYSO cry... 收藏

Study of linearity of LYSO crystal for the high energy cosmic radiation detection(HERD)facility

作     者:Zheng Quan Zhigang Wang Ming Xu Yongwei Dong Junjing Wang Guangpeng An Xin Liu Tianwei Bao Li Zhang RuijieWang Junguang Lv Bobing Wu Shuangnan Zhang 

作者机构:Key Laboratory of Particle AstrophysicsInstitute of High Energy PhysicsCASBeijing 100049China University of Chinese Academy of SciencesBeijing 100049China State Key Laboratory of Particle Detection and ElectronicsInstitute of High Energy PhysicsCASBeijing 100049China 

出 版 物:《Radiation Detection Technology and Methods》 (辐射探测技术与方法(英文))

年 卷 期:2017年第1卷第1期

页      面:21-28页

学科分类:07[理学] 070202[理学-粒子物理与原子核物理] 0702[理学-物理学] 

基  金:This research was supported by National Natural Science Foundation of China,Grant No.11327303,11473028 and 11675196 International Science and Technology Cooperation Program of China,Grant No.2015DFA10140 Interdisciplinary Innovation Team Project of Chinese Academy of Sciences(Research Team of The High Energy cosmic-Radiation Detection) Qianren start-up,Grant No.292012312D1117210 Strategic Pioneer Program in Space Science,Chinese Academy of Sciences,Grant No.XDA04075600 Youth Innovation Promotion Association of CAS,Grant No.2014009.The authors would like to thank Dr.Sun Jianchao,Dr.Zhang Xuan,Dr.Zhang Xiaofeng and Dr.Ning Zhe for their support 

主  题:HERD Calorimeter LYSO Linearity Beam test 

摘      要:The high energy cosmic-radiation detection(HERD)facility is a space mission designed for detecting cosmic ray(CR)electrons,γ-rays up to tens of TeV and CR nuclei from proton to iron up to several *** main instrument of HERD is a 3-D imaging calorimeter(CALO)composed of nearly ten thousand lutetium yttrium orthosilicate(LYSO,with cerium doping)crystal cubes.A large dynamic range of single HERD CALO Cell(HCC)is necessary to achieve HERD’s PeV observation objectives,which means that the response of HCC should maintain a good linearity from minimum ionizing particle(MIP)calibration to PeV shower *** order to study the linearity ofHCC over such a large energy range,a beam test has been implemented at the E2 and E3 beam lines of *** intensity pulsed electron beam provided by E2 line is used for producing high energy density within HCC;π^(+)/proton provided by E3 line are used *** results showthat no saturation effect occurs and the linearity ofHCCis better than 10%from 30 MeV(1MIP)to 1.1×10^(3) TeV(energy density is 93 TeV/cm^(3)),which can meet the requirement mentioned above.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分