咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Magnetic Resonance Imaging and... 收藏

Magnetic Resonance Imaging and Biomechanical Analysis of Adipose-derived Stromal Vascular Fraction Applied on Rotator Cuff Repair in Rabbits

Magnetic Resonance Imaging and Biomechanical Analysis of Adipose-derived Stromal Vascular Fraction Applied on Rotator Cuff Repair in Rabbits

作     者:Liang-Yu Lu Chun-Yan Kuang Feng Yin Lu Liang-Yu;Kuang Chun-Yan;Yin Feng

作者机构:Department of Joint and Sports Medicine East Hospital Tongji University School of Medicine Shanghai 200120 China Department of Rehabilitation East Hospital Tongji University School of Medicine Shanghai 200120 China 

出 版 物:《Chinese Medical Journal》 (中华医学杂志(英文版))

年 卷 期:2018年第131卷第1期

页      面:69-74页

核心收录:

学科分类:1002[医学-临床医学] 10[医学] 

主  题:Biomechanical Magnetic Resonance hnaging: Rotator Cuff Healing 

摘      要:Background: Adipose-derived stromal vascular fraction (ADSVF) can be applied to repair tendon and ligament tears. ADSVF treatment has a better therapeutic potential than adipose stem cells alone in promoting the healing of connective tissue injury in rabbit models. Magnetic resonance imaging (MRI) and biomechanical testing were used in this study to evaluate the efficiency of SVF in the healing of tendon-bone interface of a rotator cuff injury after reattachment. Methods: A total of 36 rabbits were studied between March and June 2016, 18 rabbits received the SVF-fibrin glue (SVF-FG) treatment and the other 18 formed the control group. ADSVF was isolated from each rabbit. A bilateral amputation of the supraspinatus tendon and parallel reconstruction was also performed on all the 36 rabbits. Then, a mixture of SVF and FG was injected into the tendon-bone interface of the SVF-FG group, whereas the control group only received FG. Tile animals were randomly sacrificed at 4, 8, and 12 weeks after surgery (n = 6 per group), respectively. The shoulders were prepared for MRI scanning and analysis of biomechanical properties. Analyses of variance were pertbrmed using SPSS 13.0. Results: MRI scanning showed that the signal-to-noise quotient of the SVF-FG group was not significantly higher than that of the control group at either 4 (20.1 ± 3.6 vs. 18.2 ± 3.4, F = 1.570, P = 0.232) or 8 weeks (20.7 ±3.3 vs. 18.0 ± 3.0, F = 2.162, P = 0.117) posttreatment, and only became significant after 12 weeks (27.5± 4.6 vs. 22.1 ± 1.9, F 4.968, P = 0.009). Biomechanical properties such as the maximum load, maximum strength, and the stiffness for the SVF-FG group were significantly greater than that for the control group at 8 weeks' posttreatment (maximum load: 166.89 ± 11.62 N vs. 99.40 ± 5.70 N, P 〈 0.001: maximum strength: 8.22 ± 1.90 N/ram vs. 5.82 ±0.68 N/ram, P 〈 0.010: and the stiffness: 34.85±3.00 Pa vs. 24.57±5.72 Pa, P 〈 0.010). Conclusion: Local application of ADSVF might lead to

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分