咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >A novel transient rotor curren... 收藏

A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

作     者:沈阳武 柯德平 孙元章 Daniel Kirschen 王轶申 胡元朝 

作者机构:School of Electrical EngineeringWuhan University Department of Electrical EngineeringUniversity of Washington 

出 版 物:《Chinese Physics B》 (中国物理B(英文版))

年 卷 期:2015年第24卷第7期

页      面:52-63页

核心收录:

学科分类:080801[工学-电机与电器] 0808[工学-电气工程] 08[工学] 

基  金:supported by the National Natural Science Foundation of China(Grant No.51307124) the Major Program of the National Natural Science Foundation of China(Grant No.51190105) 

主  题:doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support 

摘      要:A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分