Pilot plant study on ozonation and biological activated carbon process for drinking water treatment

Pilot plant study on ozonation and biological activated carbon process for drinking water treatment

作     者:KONG Ling-yu ZHANG Xiao-jian WANG Zhan-sheng 

作者机构:Department of Environmental Science and Engineering Tsinghua University Beijing 100084 China 

出 版 物:《Journal of Environmental Sciences》 (环境科学学报(英文版))

年 卷 期:2006年第18卷第2期

页      面:232-235页

核心收录:

学科分类:08[工学] 0815[工学-水利工程] 

主  题:ozonation biological activated carbon CODMn UV254 TOC AOC BDOC biostability 

摘      要:A study on advanced drinking water treatment was conducted in a pilot scale plant taking water from conventional treatment process. Ozonation-biological activated carbon process (O3-BAC) and granular activated carbon process (GAC) were evaluated based on the following parameters: CODMn, UV254, total organic carbon (TOC), assimilable organic carbon (AOC) and biodegradable dissolved organic carbon (BDOC). In this test, the average removal rates of CODMn, UV254 and TOC in O3-BAC were 18.2%, 9.0% and 10.2% higher on (AOC) than in GAC, respectively. Ozonation increased 19.3-57.6 μg Acetate-C/L in AOC-P17, 45.6-130.6 μg Acetate-C/L in AOC-NOX and 0.1-0.5 mg/L in BDOC with ozone doses of 2 8 mg/L. The optimum ozone dose for maximum AOC formation was 3 mgO3/L. BAC filtration was effective process to improve biostability.