咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >The Tissue Reactions and Chang... 收藏

The Tissue Reactions and Changes of a Surface of Various Metal Implants after Their Introduction in a Bone Tissue in Experiment

The Tissue Reactions and Changes of a Surface of Various Metal Implants after Their Introduction in a Bone Tissue in Experiment

作     者:Michael S. Toder Andrew I. Shevela Alexander A. Shevela Paul A. Zheleznyi Anna P. Zheleznaia Igor V. Mayborodin Michael S. Toder;Andrew I. Shevela;Alexander A. Shevela;Paul A. Zheleznyi;Anna P. Zheleznaia;Igor V. Mayborodin

作者机构:International Center of Implantology of iDent Novosibirsk Russia Center of New Medical Technologies Institute of Chemical Biology and Fundamental Medicine Russian Academy of Science Siberian Branch Novosibirsk Russia Novosibirsk State Medical University Novosibirsk Russia 

出 版 物:《Surgical Science》 (外科学(英文))

年 卷 期:2016年第7卷第2期

页      面:100-106页

学科分类:07[理学] 0701[理学-数学] 070101[理学-基础数学] 

主  题:Implantation of Metals Intra Bone Durability of Implant Fixing Isolation of Foreign Bodies Metal Fragments in Tissues Features of Implant Removal 

摘      要:Screw metal implants (3S, Israel) with rough or smooth polished surface were introduced in a tibial proximal condyle of not purebred rabbits. The condition of surrounding tissues in 2 and 6 months after implantation was compared by light microscopy and X-ray methods. Within 6 months after operation the considerable distinctions of radiological and morphological data were revealed not. 2 months later after introduction of implants with a rough surface the effort enclosed for its twisting is, much more, than for removal of the polished product. However, stability of fixing of implants was practically made even at 6 months. On remote rough implants there is a set of tissue scraps whereas on products with a smooth surface the tissue remains were much less. Surrounding tissues strongly join a rough surface, grow into cavities, and during removal of such products there is a considerable trauma of tissues round an implantation place. Smooth implants have the smaller area of contact with organism tissues, they are fixed due to bicortical implantation, during removal easily get out and don’t break off surrounding tissues. The signs of inflammation and formation of merged multinuclear macrophages were not found at all cases, which give evidence to the inertness of material of the mentioned articles for living organism. In some observations however and by implantation of the rough article and by introduction of polished implants, metal particles were found, but after use of the foreign body with grit-blasted treatment of surface metal was found more frequently, and its fragments had larger volume.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分