Comparison of Laryngoscopic View and Hemodynamic Changes with Flexitip McCoy and Macintosh Laryngoscope Blade in Predicted Easy and Difficult Airway

Comparison of Laryngoscopic View and Hemodynamic Changes with Flexitip McCoy and Macintosh Laryngoscope Blade in Predicted Easy and Difficult Airway

作     者:Zia Arshad Haider Abbas Jaishree Bogra Sulekha Saxena 

作者机构:Department of Anesthesiology K G Medical University Lucknow India. 

出 版 物:《Open Journal of Anesthesiology》 (麻醉学期刊(英文))

年 卷 期:2013年第3卷第5期

页      面:278-282页

学科分类:1002[医学-临床医学] 100214[医学-肿瘤学] 10[医学] 

主  题:Macintosh Blade McCoy Blade Laryngoscopy Airway 

摘      要:Objective: To compare the laryngoscopic view and the hemodynamic changes by using flexitip McCoy laryngoscope with Macintosh laryngoscope. Method: Study design-Prospective randomized controlled study. A total of 220 patients were included in the study. Patients were allocated on the basis of their airway anatomy in to two groups, one is predicted easy group and the other one was predicted difficult airway group. Among each group, half of the patient intubation was performed with Macintosh blade and the other half was intubated with the help of McCoy blade. The airway prediction was done on the basis of Mallampati grade, thyromental distance, inter incisor gap, jaw protrusion and weight of the patient. Larygoscopic view and hemodynamic changes were recorded. Results: The change in pulse rate was significantly (p = 0.01) higher among the patients of Group B (85.02 ± 10.13) as compared to Group A (79.20 ± 13.11) after induction in predicted easy patients. Similar observation was found for pulse rate after laryngoscopy among both predicted easy and difficult patients. The diastolic blood pressure was significantly (p = 0.0001) higher in Group B (86.34 ± 9.78) than Group A (77.12 ± 11.66) after induction among predicted easy patients. However, diastolic blood pressure was significantly (p = 0.0004) higher in Group A (82.00 ± 10.98) compared with Group B (75.00 ± 9.06) after induction among predicted difficult patients. The average time taken during laryngoscopy was in-significantly (p 0.05) higher in Group B (13.90 ± 5.95) compared with Group A (12.42 ± 3.58) among predicted easy patients. However, the time taken was significantly (p = 0.0001) higher in Group A (20.83 ± 2.47) than Group B (12.66 ± 3.0) in predicted difficult patients. A majority of the patients of both the groups were in Grade I (Group A = 61.8%, Group B = 81.8%) followed by Grade II (Group A = 38.2%, Group B = 18.2%) among predicted easy patients. Conclusion: It was concluded that the McCoy blade may

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分