咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Beam transport experiment with... 收藏

Beam transport experiment with a new kicker control system on the HIRFL

Beam transport experiment with a new kicker control system on the HIRFL

作     者:王彦瑜 周德泰 罗金富 张建川 周文雄 倪发福 尹俊 尹佳 原有进 上官靖斌 

作者机构:Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of the Chinese Academy of Sciences Beijing 100049 China College of Power Engineering Chongqing University Chongqing 400044 China 

出 版 物:《Chinese Physics C》 (中国物理C(英文版))

年 卷 期:2016年第40卷第4期

页      面:113-117页

核心收录:

学科分类:08[工学] 082701[工学-核能科学与工程] 0827[工学-核科学与技术] 

基  金:Supported by National Natural Science Foundation of China(U1232123) 

主  题:completed installed Lanzhou supplies inefficient missed trigger monolithic diagnostic adjusted 

摘      要:A kicker control system is used for beam extraction and injection between two cooling storage rings(CSRs) at the Heavy Ion Research Facility in Lanzhou(HIRFL). To meet the requirements of special physics experiments, the kicker controller has been upgraded, with a new controller designed based on ARM+DSP+FPGA technology and monolithic circuit architecture, which can achieve a precision time delay of 2.5 ns. In September2014, the new kicker control system was installed in the kicker field, and the test experiment using the system was completed. In addition, a pre-trigger signal was provided by the controller, which was designed to synchronize the beam diagnostic system and physics experiments. Experimental results indicate that the phenomena of “missed kickand “inefficient kick were not observed, and the multichannel trigger signal delay could be adjusted individually for kick power supplies in digitization; thus, the beam transport efficiency was improved compared with that of the original system. The fast extraction and injection experiment was successfully completed based on the new kicker control systems for HIRFL.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分