咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Development and validation of ... 收藏

Development and validation of a rapid UPLC/MS method for the simultaneous determination of I3C, DIM, and related metabolites and its application to pharmacokinetics studies

Development and validation of a rapid UPLC/MS method for the simultaneous determination of I3C, DIM, and related metabolites and its application to pharmacokinetics studies

作     者:Yury Gomez Hu Wang Ah-Ng Tony Kong 

作者机构:Graduate Program in Pharmaceutical Science Ernest Mario School of Pharmacy Rutgers The State University of New Jersey Department of Pharmaceutics Ernest Mario School of Pharmacy Rutgers The State University of New Jersey 

出 版 物:《Journal of Chinese Pharmaceutical Sciences》 (中国药学(英文版))

年 卷 期:2016年第25卷第7期

页      面:477-488页

核心收录:

学科分类:1008[医学-中药学(可授医学、理学学位)] 1006[医学-中西医结合] 100602[医学-中西医结合临床] 10[医学] 

基  金:R01 CA118947 R01 CA152826 from National Cancer Institute(NCI) R01AT007065 from the National Center for Complementary and Alternative Medicines(NCCAM) the Office of Dietary Supplements(ODS) the National Institute of Health Grant R01 CA073674 

主  题:UPLC/MS Indole-3-Carbinol Diindolylmethane Pharmacokinetics Single-dose administration Sprague-Dawley Rats 

摘      要:Indole-3-carbinol(I3C) and diindolylmethane(DIM) are naturally derived dietary phytochemicals with promising anti-cancer properties that have been demonstrated both in vitro and in vivo. Using reversed-phase ultra-performance liquid chromatography(UPLC) coupled with mass spectrometry(MS), a rapid, specific, and high throughput method was developed and validated for the quantification and identification of I3 C, DIM, and other I3 C metabolites in plasma. Samples containing I3 C or DIM and the internal standard 4-methoxy indole(IS) were extracted using a liquid-liquid extraction technique. The mean recovery was 96.21% for I3 C and 108.5% for DIM. Separation was achieved using a Waters Acquity UPLC HSS T3, 1.8 μm, 2.1 mm×150 mm column and acetonitrile–water gradient elution. The flow rate was 0.3 m L/min and the run time was 9 min. The limits of detection and quantification for I3 C and DIM were 15 ng/m L and 25 ng/m L, respectively. Calibration curves for I3 C and DIM were linear(r20.99) over a concentration range of 0.025–20 μg/m L. Precision, accuracy, and stability analysis fulfilled the CDER guidelines criteria. The method was successfully applied to the determination of the pharmacokinetic parameters of I3 C or DIM after oral, intravenous, or intraperitoneal administration to Sprague Dawley rats. The method described here is superior over existing analytical methods for I3 C and its metabolites in terms of sensitivity, speed, and separation.

读者评论 与其他读者分享你的观点