文献详情 >Study on drying and combustion... 收藏

Study on drying and combustion process in grate-CFB incinerator

Study on drying and combustion process in grate-CFB incinerator

作     者:QingHai Li YanGuo Zhang MeiQian Chen AiHong Meng ChangHe Chen 

作者机构:Key Laboratory for Thermal Science and Power Engineering of Ministry of Education Tsinghua University Beijing 100084 China School of Mechanical Electronical and Control Engineering Beijing Jiaotong University Beijing 100044 China 

出 版 物:《Science China(Technological Sciences)》 (中国科学(技术科学英文版))

年 卷 期:2009年第52卷第5期

页      面:1153-1160页

核心收录:

学科分类:080703[工学-动力机械及工程] 08[工学] 0807[工学-动力工程及工程热物理] 

基  金:Supported by the National Natural Science Foundation of China (Grant No. 50776007) 

主  题:drying waste incineration grate-CFB combustion model 

摘      要:The drying and combustion process in the combined grate and circulating fluidized bed (grate-CFB) municipal solid waste (MSW) incinerator was investigated experimentally and mathematically. The drying grate bed was simulated by a muffle furnace, which could be controlled at a constant temperature level. The kind of wastes, thickness of waste layer fed and temperature were chosen as the adjustable parameters to study their effect on the drying process. The experimental results indicated that the hydrophilic wastes were more difficult to be dried than the hydrophobic wastes. The higher the temperature is the easier the waste is to be dried. The thinner waste layer is favorable to drying the waste. The pyrolysis experiment in the furnace showed that the higher temperature level could reduce the conversion rate of carbon to carbon monoxide. The semi-empirical mathematical model that included the bed material distribution submodel, volatile matter release submodel, carbon particle combustion submodel and so on was proposed. A 260 t/d grate-CFB incinerator was modeled and the model predicted bulk density agreed with the measured value from industrial field test. The predicted flue gas (e.g. CO2, CO) concentration deviated slightly from the industrial test data. The parameters and variables used in the model were determined by the experiments or practical field test. This model can be used to design the grate-CFB incinerator and guide its operation.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分